SSF101 THRU SSF107
1.0 AMP SURFACE MOUNT FAST RECOVERY RECTIFIERS
VOLTAGE RANGE
50 to 1000 Volts
CURRENT
1.0 Ampere
FEATURES
* Ideal for surface mount applications
* Easy pick and place
SS
.106(2.7)
.098(2.5)
* Built-in strain relief
* Fast switching speed
.051(1.3)
.043(1.1)
MECHANICAL DATA
.144(3.65)
.136(3.45)
* Case: Molded plastic
.007(0.17)
.005(0.13)
* Epoxy: UL 94V-0 rate flame retardant
* Metallurgically bonded construction
* Polarity: Color band denotes cathode end
* Mounting position: Any
.037(0.95)
.033(0.85)
.067(1.7)
.059(1.5)
.033(0.85)
.022(0.55)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating 25 C ambient temperature uniess otherwies specified.
Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
SSF101 SSF102 SSF103 SSF104 SSF105 SSF106 SSF107 UNITS
TYPE NUMBER
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
50
35
50
100
70
200
140
200
400
280
400
600
420
600
800
560
800
1000
700
V
V
V
Maximum DC Blocking Voltage
100
1000
Maximum Average Forward Rectified Current
at Ta=25 C
1.0
A
Peak Forward Surge Current, 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Maximum Instantaneous Forward Voltage at 1.0A
30
1.3
5.0
A
V
Maximum DC Reverse Current
Ta=25 C
A
at Rated DC Blocking Voltage
Ta=100 C
100
A
Maximum Reverse Recovery Time (Note 1)
150
250
500
nS
Typical Junction Capacitance (Note 2)
15
80
pF
C/W
C
Typical Thermal Resistance RqJA (Note 3)
Operating and Storage Temperature Range TJ, TSTG
-65 +150
F11
F12
F13
F14
F15
F16
F17
Marking Code
NOTES:
1. Reverse Recovery Time test condition: IF=0.5A, IR=1.0A, IRR=0.25A
2. Measured at 1MHz and applied reverse voltage of 4.0V D.C.
3. Thermal Resistance from Junction to Ambient.