APPLICABLE STANDARD
Operating
UL,C-UL、TUV STANDARD (Appendix 1)
-40 ℃ to +105 ℃(Note 1)
Storage Temperature
Range
(Included temperature rise
caused by current-carrying)
Power: (Appendix 1)
-40 ℃ to +60 ℃(Note 2)
Temperature Range
Power:150A(UL,C-UL,TUV) (Appendix 1)
:210A(Derating curve:25℃)
(Appendix 2)
Voltage
RATING
Signal:AC,DC 250 V
Current
Signal:1A
14sq to 50sq
Applicable Wire
※The Rating Current for each applicable wire
size can be found in table 3.
(AWG#5 to AWG#1/0)
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT
AT
CONSTRUCTION
General Examination
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
x x
x x
Marking
ELECTRICAL CHARACTEREISTICS
Contact Resistance
Power:DC 1 A
Power:0.3 mΩ MAX.
x x
Signal:60 mΩ MAX. (Note 3)
(Assurance test is only signal)
5000 MΩ MIN.
Signal:100 mA(DC OR 1000Hz)MAX.
250 V DC
Insulation Resistance
Voltage Proof
x -
Power:2000 V AC. for 1 min.
Signal:650 V AC. for 1 min.
No flashover or breakdown.
x x
(Assurance test is only signal)
MECHANICAL CHARACTERISTICS
Mating and Unmating Forces Measured by applicable connector at a speed of
Mating force : 137.2 N MAX.
Unmating force : 137.2 N MAX.
x -
x -
x -
30 mm 3 mm/min.
Mechanical Operation
100 times insertions and extractions at a speed of 600
times/hour.
① Contact resistance change:Power 0.5 mΩ MAX.
Signal 40 mΩ MAX. (Note 3)
(GT8E of signal part:30 times insertions and
extraction)
② No damage, crack and looseness of parts.
Vibration
Shock
Frequency : 10 to 55 Hz, singe amplitude 0.75 mm,
① No electrical discontinuity of 10 μs.
② No damage, crack and looseness of parts.
x -
at 5 min/cycle, 10 cycles each in 3 axial directions.
30 cycles in total.
490 m/s2, duration of pulse 11 ms, for 3 times
x -
x -
in 3 both axial directions.
ENVIRONMENTAL CHARACTERISTICS
Temperature -40 → 105 ℃
① Contact resistance change:Power 0.5 mΩ MAX.
Signal 40 mΩ MAX. (Note 3)
Time 30 → 30 min
Rapid Change of Temperature Chamber transfer time is 2 to 3 min.
Conduct 5 cycles of above cycles (mated)
② Insulation resistance : 1000 MΩ MIN.
③ No damage, crack and looseness of parts.
and exposed in the room temperature for 1 to 2 hours.
After exposure at temperature 402 C, humidity 90 to
95 ,for 96 h (mated), exposed at room temperatrure
for 1 to 2 hour.
Humidity Life
① Contact resistance change:Power 0.5 mΩ MAX.
Signal 40 mΩ MAX. (Note 3)
x -
② Insulation resistance : 1000 MΩ MIN.
③ No damage, crack and looseness of parts.
After exposure at temperature 1052 C,
humidity for 96 h (mated), exposed at room
temperatrure for 1 to 2 hour.
Heat Resistance
① Contact resistance change:Power 0.5 mΩ MAX.
Signal 40 mΩ MAX. (Note 3)
x -
② Insulation resistance : 1000 MΩ MIN.
③ No damage, crack and looseness of parts.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
△
APPROVED
CHECKED
DESIGNED
DRAWN
MN.KENJO
KG.OKITA
20230130
20230130
20230127
20230127
REMARK
MO.SHIMOYAMA
Unless otherwise specified, refer to IEC 60512.
MO.SHIMOYAMA
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
ELC-128100-11-00
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
FORM HD0011-2-1
PART NO.
CODE NO
PS3-2UP/12P/16P(11)
CL0236-1044-8-11
1/9