Applicable standard
Operating
Storage
Temperature range
Storage
-40 C to +105C (Note1)
20% to 80%
-10 C to +60C (Note2)
Temperature range
Operating
Rating
40% to 70% (Note2)
Humidity range
Applicable
Humidity range
Voltage
DF62W#-※S-2.2C(%%)
AC/DC
250V
Connector
1 Applicable contact
1 Current
AWG 22 : 3A
AWG 24 : 2A
DF62W-**PC**
1 Applicable
φ0.98 to φ1.2mm
insulation diameter
AWG 26 to 30 : 1A
Specifications
Test method
Item
Requirements
QT AT
Construction
General examination
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
X
X
X
X
Marking
Electric characteristics
Insulation resistance
500 V DC.
1000 M MIN.
No flashover or breakdown.
-
-
X
X
650 V AC for 1 min.
Voltage proof
Mechanical characteristics
30 times insertion and extraction.
Mechanical operation
No damage, crack or looseness of parts.
-
X
Frequency 10 to 55 Hz, single amplitude
0.75 mm, at 10 cycles for 3 direction.
490 m/s2 duration of pulse 11 ms at 3 times each for
3 both axial directions.
Vibration
Shock
No damage, crack or looseness of parts.
No damage, crack or looseness of parts.
-
-
X
X
Environmental characteristics
Damp heat
Exposed at 40 ± 2℃ , 90 to 95 %, 96 h.
①Insulation resistance: 1000 MΩ Min.
-
-
X
X
(Steady state)
(After leaving the room temperature for 1 - 2h.)
②No damage, crack or looseness of parts.
Rapid change of temperature Temperature -55℃→ +85℃
Time 30min→ 30min
①Insulation resistance: 1000 MΩ Min.
②No damage, crack or looseness of parts.
Under 5 cycles.
(The transferring time of the tank is 2 - 3 min)
(After leaving the room temperature for 1 - 2h.)
Note 1: Include the temperature rising by current.
Note 2: Apply to the condition of long term storage for unused products before PCB on board. After PCB on board, operating temperature
and humidity range is applied for interim strage during transportation.
Count
Description of revisions
Designed
Checked
Date
1
△
3
DIS-H-00002809
YK.YAMAGUCHI
TS.FUKUSHIMA
HS.OKAWA
17.05.11
17.03.23
17.03.22
17.03.21
17.03.21
Remarks
Approved
Checked
Designed
Drawn
TS.FUKUSHIMA
YK.YAMAGUCHI
MI.SAKIMURA
Unless otherwise specified, refer to IEC 60512.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
Drawing No.
ELC-370676-00-00
DF62WC-9EP-2.2C
Part No.
Specification sheet
HIROSE ELECTRIC CO., LTD.
1
△
1/1
Code No.
CL544-1037-0-00