450W/650W/1000W Modular Power
MP series
Features :
ZVT technology to reduce power dissipation and improve efficiency
Various output configuration is selectable
Built in active PFC, PF>0.95
Universal AC input/ full range
Remote Control on every individual output module
Remote Sense on every individual output module(MS-75,150,300)
Built in parallel function(MS-300)
Protections: Short circuit / Overload / Over voltage for all output modules
Additional 12V/0.1A auxiliary output for remote control
Cooling by built-in DC fan with fan alarm function
3 years warranty
Output Configuration Guide
MP
-
-
Single output(MS-150)
1 SLOT (150W max.)
Single output(MS-300)
2 SLOT (300W max.)
Single output(MS-75)
1 SLOT (75W max.)
Dual output(MD-100)
1 SLOT (100W max.)
SLOT1 SLOT2 SLOT3 SLOT4 SLOT5 SLOT6 SLOT7
Voltage code Voltage
450/650/1K0(450W/650W/1000W)
Modular Power with PFC
Voltage code Voltage
Voltage code Voltage
Voltage code Voltage
A
B
C
D
E
F
G
H
I
2V
3.3V
5V
2A
2B
2C
2D
2E
2F
2G
2H
2I
2V
3.3V
5V
L
M
N
O
P
3.3V
5V
5V
R
450W/650W(5SLOT)
1000W(7SLOT)
Parallel or option code
(See Table 1.)
5V
12V
15V
24V
48V
5V
S
7.5V
12V
15V
18V
24V
27V
33V
48V
7.5V
12V
15V
18V
24V
27V
33V
48V
12V
Example: MP1K0- A
2
E
#
S
2
K
5V
T
15V
Q
SLOT1
O/P:2V@25A
24V
U
5V
SLOT2,3
24V
V
O/P:12V@25A
SLOT4
Blank Slot
SLOT5
O/P:5V@10A
J
2J
12V
K
2K
12V
W
12V
15V
X
15V
12V@4.2A
SLOT6,7
O/P:48V@6.3A
SPECIFICATION
MODEL
PFC-450
PFC-650
PFC-1000
VOLTAGE RANGE
85 ~ 264VAC
47 ~ 63Hz
120 ~370VDC
FREQUENCY RANGE
POWER FACTOR
EFFICIENCY
PF>0.95/230VAC
PF>0.98/115VAC at full load
INPUT
Note.1 83% typ.
84% typ.
84% typ.
AC CURRENT
9A/115VAC
30A/115VAC
4.5A/230VAC
50A/230VAC
6.3A/115VAC
25A/115VAC
<1.5mA/240VAC
450W max.
3.2A/230VAC
40A/230VAC
13.5A/115VAC
20A/115VAC
6.7A/230VAC
40A/230VAC
INRUSH CURRENT
LEAKAGE CURRENT
TOTAL OUTPUT POWER
650W max.
1000W max.
OUTPUT
Thermal switch detect on the heatsink of power MOSFET
OVER TEMPERATURE
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
Output shutdown when FAN is malfunction
PROTECTION
FAN ALARM
REMOTE CONTROL
AUXILIARY POWER(AUX)
RC+/RC-: 0 ~ 0.8V or Short, Power ON
RC+/RC-: 4 ~ 12V or Open, Power OFF
FUNCTION
12V@0.1A(only for Remote ON/OFF Control)
-20 ~ +70 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
ENVIRONMENT
-40 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
SAFETY &
ISOLATION RESISTANCE
EMC
(Note 5)
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
EMS IMMUNITY
DIMENSION
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN61000-6-1, EN61204-3, light industry level, criteria A
254*127*63.5mm (L*W*H)
278*127*63.5mm (L*W*H)
278*177.8*63.5mm (L*W*H)
OTHERS
PACKING
1.8Kg(typ.); 6pcs / 11.8Kg / 1.25CUFT
2.16Kg(typ.); 6pcs / 14Kg / 1.34CUFT
3Kg(typ.); 6pcs /19Kg / 1.74CUFT
File Name:MP-450,650,1K0-SPEC 2008-08-05