Description
• Axial Leaded
• Fast Acting, Solid Matrix Construction
• High Temperature Thermoplastic Body, UL 94 VO
• Tin-lead plated copper Lead Wires, .025" diameter
ELECTRICAL CHARACTERISTICS
% of Amp Rating (0-10A)
Opening Time
4 hours minimum
5 seconds maximum
100%
250%
Agency Information
• Terminal Strength: MIL-STD-202, Method 211, Test
Condition A, will withstand 7 lb. axial pull test.
• Thermal Shock: MIL-STD-202, Method 107, Test
Condition B, -65°C to 125°C
• Thermal Cycle: EIA-STD-RS-186-C, Test Condition A,
-55°C to 85°C
• UL Recognition Guide & File Numbers:
JDYX2 & E19180
• CSA Certification File & Class Numbers: 053787 C 00 &
1422 30 (0 - 1/8A); 053787 C 00 & 1422 01 (1/4A - 8A)
Ordering
• Vibration: MIL-STD-202, Method 204, Test Condition C,
(55 to 2000 HZ, 10G’s peak)
• Wave Soldering: Maximum reservoir temperature
260°C, 10 second maximum exposure, .125" from body.
• Specify product code and packaging code
Environmental Data
• Life Test: 2000 hours at 80% rated current, 55°C
• Moisture Resistance: MIL-STD-202, Method 106, 90%
relative humidity at 65°C.
• Operating Temperature: -55°C to 125°C with proper fuse
derating
• Resistance to Soldering Heat: MIL-STD-202, Method
210, Test Condition C (260°C)
• Salt Spray: MIL-STD-202, Method 101, Test Condition B
• Shock: MIL-STD-202, Method 213, Test Condition I,
100G’s for 6 milliseconds
mm
Dimensions
⁄(inches)
0.005"
0.13mm
*All tolerances:
1.13"
28.58mm
1.13"
28.58mm
.297"
7.54mm
.12"
3.10mm
.025"
0.64mm
• Solderability: MIL-STD-202, Method 208
SPECIFICATIONS
2
2
Rated
Voltage
Interrupting
Rating
Pre-arching
Typical Total Clearing
Typical Voltage
Drop Volts at
1
2
2
2
2
Product
Code
MCR-1/16 125V
I t (A sec)
I t (A sec)
AC
DC
AC
DC
AC
1.1 x 10-6
4.3 x 10-6
8.0 x 10-5
9.7 x 10-5
7.4 x 10-4
1.3 x 10-3
.01
.03
.09
.19
.35
.56
.96
1.82
1.48
DC
AC
DC
1.5 x 10-7
8.7 x 10-7
1.3 x 10-6
8.3 x 10-6
6.8 x 10-5
9.2 x 10-5
.01
.03
.08
.17
.32
.43
.77
1.51
.58
100% Rated
2.33
1.52
.76
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
90V
50A
50A
50A
50A
50A
50A
50A
50A
50A
50A
50A
50A
50A
50A
50A
50A
300A
300A
300A
300A
300A
300A
300A
300A
300A
300A
300A
300A
300A
300A
300A
300A
1.0 x 10-7
7.1 x 10-7
1.0 x 10-6
6.7 x 10-6
5.4 x 10-5
7.4 x 10-5
.01
1.8 x 10-6
7.3 x 10-6
1.2 x 10-4
1.1 x 10-4
6.2 x 10-3
7.5 x 10-2
.02
MCR-1/8
MCR-1/4
MCR-3/8
MCR-1/2
MCR-3/4
MCR-1
MCR-1 1/2 125V
MCR-2 125V
MCR-2 1/2 125V
MCR-3 125V
MCR-3 1/2 125V
125V
125V
125V
125V
125V
125V
.73
.65
.55
.24
.20
.16
.15
.15
.14
.13
.11
.10
.02
.07
.14
.28
.37
.67
1.34
.49
.04
.11
.25
.45
.83
1.37
2.53
2.02
MCR-4
MCR-5
MCR-7
MCR-10
125V
125V
60V
60V
90V
3.62
1.16
4.41
1.38
.08
1. Interrupting ratings were measured at 100% (1/16 to 5) and 100% (7, 10) power factors on AC, and a time constant less than 1 ms. on DC.
2. I2t was measured at 50 amps 125 VAC, .95PF, (random closing angle) and 300 amps 125 VDC, TC <1ms. for 1/16 through 5 amps and 50 amps 60 VAC, .95PF,
(random closing angle), and 300 amps 90 VDC, TC <1ms. for the 7 and 10 amp fuses.
NOTE: All values shown above are typical.
• Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is recommended, with further derating required