DSEI 12 IFAVM = 11 A
VRRM = 1200 V
Fast Recovery
Epitaxial Diode (FRED)
trr
= 50 ns
TO-220 AC
C
A
VRSM
V
VRRM
V
Type
C
A
C
1200
1200
DSEI 12-12A
A = Anode, C = Cathode
Symbol
IFRMS
Test Conditions
Maximum Ratings
Features
①
International standard package
TVJ = TVJM
25
11
150
A
A
A
IFAVM
IFRM
①
TC = 100°C; rectangular, d = 0.5
tP < 10 ms; rep. rating, pulse width limited by TVJM
JEDEC TO-220 AC
①
①
①
①
①
①
Planar passivated chips
Very short recovery time
Extremely low switching losses
Low IRM-values
Soft recovery behaviour
Epoxy meets UL 94V-0
IFSM
TVJ = 45°C; t = 10 ms (50 Hz), sine
75
80
A
A
t = 8.3 ms (60 Hz), sine
TVJ = 150°C; t = 10 ms (50 Hz), sine
65
70
A
A
t = 8.3 ms (60 Hz), sine
I2t
TVJ = 45°C
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
28
27
A2s
A2s
Applications
TVJ = 150°C; t = 10 ms (50 Hz), sine
21
20
A2s
A2s
t = 8.3 ms (60 Hz), sine
①
Antiparallel diode for high frequency
switching devices
TVJ
TVJM
Tstg
-40...+150
150
-40...+150
°C
°C
°C
①
①
①
Anti saturation diode
Snubber diode
Free wheeling diode in converters
and motor control circuits
Rectifiers in switch mode power
supplies (SMPS)
Inductive heating and melting
Uninterruptible power supplies (UPS)
Ultrasonic cleaners and welders
Ptot
Md
TC = 25°C
78
0.4...0.6
2
W
Nm
g
①
Mounting torque
Weight
Symbol
IR
①
①
①
Test Conditions
Characteristic Values
max.
typ.
Advantages
TVJ = 25°C
TVJ = 25°C
TVJ = 125°C VR = 0.8 • VRRM
VR = VRRM
VR = 0.8 • VRRM
250
150
4
mA
mA
mA
①
High reliability circuit operation
Low voltage peaks for reduced
protection circuits
Low noise switching
Low losses
Operating at lower temperature or
space saving by reduced cooling
①
VF
IF = 12 A;
TVJ = 150°C
TVJ = 25°C
2.2
2.6
V
V
①
①
VT0
rT
For power-loss calculations only
TVJ = TVJM
1.65
46.2
V
mW
①
RthJC
RthCK
RthJA
1.6
K/W
K/W
K/W
0.5
60
70
trr
IF = 1 A; -di/dt = 50 A/ms; VR = 30 V; TVJ = 25°C
50
ns
A
IRM
VR = 540 V; IF = 12 A; -diF/dt = 100 A/ms
L £ 0.05 mH; TVJ = 100°C
6.5
7.2
① IFAVM rating includes reverse blocking losses at TVJM, VR = 0.8 VRRM, duty cycle d = 0.5
Data according to IEC 60747
IXYS reserves the right to change limits, test conditions and dimensions
© 2000 IXYS All rights reserved
1 - 2