74AUP1Z125
NXP Semiconductors
Low-power X-tal driver with enable and internal resistor; 3-state
Table 7.
Static characteristics …continued
At recommended operating conditions; voltages are referenced to GND (ground = 0 V).
Symbol Parameter
VOL LOW-level output voltage
Conditions
Min
Typ
Max
Unit
Y output; VI at X1 input = VIH or VIL
IO = 20 A; VCC = 0.8 V to 3.6 V
IO = 1.1 mA; VCC = 1.1 V
IO = 1.7 mA; VCC = 1.4 V
IO = 1.9 mA; VCC = 1.65 V
IO = 2.3 mA; VCC = 2.3 V
IO = 3.1 mA; VCC = 2.3 V
IO = 2.7 mA; VCC = 3.0 V
IO = 4.0 mA; VCC = 3.0 V
X2 output; VI = GND or VCC
IO = 20 A; VCC = 0.8 V to 3.6 V
IO = 1.1 mA; VCC = 1.1 V
IO = 1.7 mA; VCC = 1.4 V
IO = 1.9 mA; VCC = 1.65 V
IO = 2.3 mA; VCC = 2.3 V
IO = 3.1 mA; VCC = 2.3 V
IO = 2.7 mA; VCC = 3.0 V
IO = 4.0 mA; VCC = 3.0 V
X1 input
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0.1
V
V
V
V
V
V
V
V
0.3 VCC
0.31
0.31
0.31
0.44
0.31
0.44
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0.1
V
V
V
V
V
V
V
V
0.3 VCC
0.31
0.31
0.31
0.44
0.31
0.44
II
input leakage current
VI = EN = VCC; VCC = 0 V to 3.6 V
EN input
-
-
-
-
0.1
0.1
A
A
VI = GND to 3.6 V;
VCC = 0 V to 3.6 V
Ipu
pull-up current
X1 input; EN = VCC
VI = GND; VCC = 0.8 V to 3.6 V
-
-
-
-
15
A
A
IOZ
OFF-state output current
Y output; VO = 0 V to 3.6 V; VCC = 0
V to 3.6 V; EN = VCC
0.1
[1]
[1]
IOFF
power-off leakage current VI or VO = 0 V to 3.6 V; VCC = 0 V
-
-
-
-
0.2
0.2
A
A
IOFF
additional power-off
leakage current
VI or VO = 0 V to 3.6 V;
VCC = 0 V to 0.2 V
ICC
supply current
VI = GND or VCC; IO = 0 A;
-
-
-
-
-
75
40
-
A
A
pF
pF
V
CC = 0.8 V to 3.6 V
EN input
VI = VCC 0.6 V; IO = 0 A;
VCC = 3.3 V
X1 input
ICC
additional supply current
-
CI
input capacitance
VCC = 0 V to 3.6 V;
VI = GND or VCC
1.3
0.8
EN input
VCC = 0 V to 3.6 V;
VI = GND or VCC
-
74AUP1Z125
All information provided in this document is subject to legal disclaimers.
© NXP B.V. 2011. All rights reserved.
Product data sheet
Rev. 4 — 1 December 2011
6 of 32