74AUP1Z125
NXP Semiconductors
Low-power X-tal driver with enable and internal resistor; 3-state
8. Limiting values
Table 5.
Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134). Voltages are referenced to GND (ground = 0 V).
Symbol
VCC
IIK
Parameter
Conditions
Min
0.5
50
0.5
50
0.5
-
Max
+4.6
-
Unit
V
supply voltage
input clamping current
input voltage
VI < 0 V
mA
V
[1]
[1]
VI
+4.6
-
IOK
output clamping current
output voltage
VO < 0 V
mA
V
VO
Active mode and Power-down mode
VO = 0 V to VCC
+4.6
20
50
IO
output current
mA
mA
mA
C
ICC
supply current
-
IGND
Tstg
Ptot
ground current
50
65
-
-
storage temperature
total power dissipation
+150
250
[2]
Tamb = 40 C to +125 C
mW
[1] The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
[2] For SC-88 packages: above 87.5 C the value of Ptot derates linearly with 4.0 mW/K.
For XSON6 packages: above 118 C the value of Ptot derates linearly with 7.8 mW/K.
9. Recommended operating conditions
Table 6.
Symbol
VCC
Recommended operating conditions
Parameter
Conditions
Min
Max
3.6
Unit
supply voltage
0.8
0
V
VI
input voltage
3.6
V
VO
output voltage
0
VCC
+125
200
V
Tamb
t/V
ambient temperature
40
-
C
ns/V
input transition rise and fall rate VCC = 0.8 V to 3.6 V
74AUP1Z125
All information provided in this document is subject to legal disclaimers.
© NXP B.V. 2011. All rights reserved.
Product data sheet
Rev. 4 — 1 December 2011
4 of 32