Signal Relays
AXICOM
IM - B Relay
2
n
n
n
n
n
n
n
Minimum board-space 60mm
Slim line 10x6mm (0.39x0.24”) and low profile 5.65mm (0.222”)
Switching power 60W/62.5VA
Switching voltage 220VDC/250VAC
Switching current 2A
Bifurcated contacts
IM_AB
High mechanical shock resistance
Typical applications
Telecommunication, access and transmission equipment, optical network
terminals, modems, office and business equipment, consumer electronics,
measurement and Test equipment, industrial control, medical equipment
U
Approvals
UL 508 File No. E 111441
Technical data of approved types on request
110VDC, 0.3A, 33W
220VDC, 0.27A, 60W
125VAC, 0.5A, 62.5W
250VAC, 0.25A, 62.5W
108 operations
Contact Data
Contact arrangement
Max. switching voltage
Rated current
1 form A (1 NO)
220VDC, 250VAC
2A
Mechanical endurance
Limiting continuous current
Switching power
Contact material
2A
60W, 62.5VA
PdRu
Au covered
twin contacts
100µV
Coil Data
Magnetic system
Coil voltage range
Max. coil temperature
Thermal resistance
monostable, bistable
1.5 to 24VDC
125°C
Contact style
Minimum switching voltage
Initial contact resistance
Thermoelectric potential
Operate time
<100mΩ at 10mA/30mV
<10µV
typ. 1ms, max. 3ms
<150K/W
Coil versions, standard version, monostable, 1 coil
Release time
without diode in parallel
with diode in parallel
Bounce time max.
Electrical endurance
at contact application 0
(≤ 30mV / ≤ 10mA)
cable load open end
resistive, 125VDC / 0.24A - 30W
resistive, 220 VDC / 0.27A - 60W
resistive, 250VAC / 0.25A - 62.5VA
resistive, 30VDC / 1A - 30W
resistive, 30VDC / 2A - 60W
Coil
code
Rated
voltage
VDC
3.0
4.5
5.0
Operate
voltage
VDC
2.25
3.38
3.75
9.00
Release
voltage
VDC
0.30
0.45
0.50
1.20
Coil
resistance
Ω 10ꢀ
64
145
178
1029
Rated coil
power
mW
typ. 1ms, max. 3ms
typ. 3ms, max. 5ms
typ. 1ms, max. 5ms
01
02
03
06
140
140
140
140
min. 2.5x106 operations
min. 2.0x106 operations
min. 5x105 operations
min. 1x105 operations
min. 1x105 operations
min. 5x105 operations
min. 1x105 operations
12.0
All figures are given for coil without pre-energization, at ambient temperature +23°C
Insulation
C*
Coil operating range
Contact data (continued)
UL contact rating
30VDC, 2A, 60W, NO only
high
Max. DC load breaking capacity
resistive load
DC current [A]
1
01-2016, Rev. 0116
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company