5秒后页面跳转
MK9151 PDF预览

MK9151

更新时间: 2024-09-12 22:30:07
品牌 Logo 应用领域
其他 - ETC 继电器
页数 文件大小 规格书
2页 66K
描述
Level sensing relay MK 9151 varimeter

MK9151 数据手册

 浏览型号MK9151的Datasheet PDF文件第2页 
Monitoring technique  
Level sensing relay MK 9151  
varimeter  
According to IEC/EN 60 255, DIN VDE 0435-303  
3 probe connections for 2-point and 1-point level control  
Also for use as moisture detector  
High interference resistance of the measuring circuit, which is  
isolated from the mains  
Max. wire length to the probes: 1500 m  
Large setting range: 2 ... 450 kΩ  
this permits differentiation between fluid and foam  
Adjustable response and release time delay: 0,2 ... 20 s  
Programmable for open circuit operation (without bridge)  
or closed circuit operation(bridge X1-X2 or X1-COM)  
For auxiliary voltages of 24 ... 415 V AC or 24 V DC  
Green LED for operation  
Yellow LED for contact position  
1 or 2 changeover contacts  
Also available with sealable transparent cover  
Available with safe separation according to IEC/EN 61 140,  
IEC/EN 60 947-1  
Function diagrams  
Width 22,5 mm  
Supply U  
H
0
Approvals and marking  
Level / Niveau  
*
MAX  
Canada / USA  
* see variants  
11 - 14  
Application  
COM X1 11 - 12  
t
t
t
t
t
Level monitoring and control for conductive liquids and powders,  
e.g. maximum and minimum filling levels, overfilling and protection  
against dry running  
Monitoring and control of the mixing ratio of conductive liquids  
General resistance monitoring tasks, e.g. limit temperature  
detection with PTC  
11 - 14  
COM X1 11 - 12  
t
M6620_d  
1-point level control  
Indicators  
Supply U  
H
green LED:  
yellow LED:  
on, when supply connected  
on, when output relay active  
0
Level / Niveau  
Notes  
MAX  
MIN  
All commercially available probes are suitable.  
The reference probe for level measurement is generally located at the  
lowest point of the container and must always be connected to the "COM"  
terminal. The container itself can be used as a reference probe if it  
consists of conductive material.  
11 - 14  
COM X1 11 - 12  
t
t
t
t
t
t
11 - 14  
COM X1 11 - 12  
1-point level control (see Figure) is especially suitable for protection  
against overfilling and dry running on containers with a free inlet/outlet.  
In this configuration, all that is required besides the reference probe  
"COM" is the "MAX", which must be located at the desired limit level. The  
output relay switches over after the set delay time if the fluid level  
exceeds or falls below the limit level, which permits fluid to be pumped  
out or added.  
M6621_f  
2-point level control  
Circuit diagrams  
A1 11  
A1 11 21  
MIN MAX COM  
MIN MAX COM  
A2 X1 COM  
11  
21  
A2 X1 X2  
11  
MIN  
A1  
MAX 12 14 22 24  
A1 MIN  
MAX COM  
12 14  
X1 X2  
12 14 A2  
22 24 X1  
12 14 A2  
M7660_a  
M7659_a  
MK 9151.11  
MK 9151.12  
All technical data in this list relate to the state at the moment of edition. We reserve the right  
for technical improvements and changes at any time.  
MK9151/22.04.04d  
1

与MK9151相关器件

型号 品牌 获取价格 描述 数据表
MK9173-01 ICSI

获取价格

Video Genlock PLL
MK9173-01CS08 ICSI

获取价格

Video Genlock PLL
MK9173-01CS08LF IDT

获取价格

PLL Based Clock Driver, 9173 Series, 2 True Output(s), 0 Inverted Output(s), CMOS, PDSO8,
MK9173-01CS08T ICSI

获取价格

Video Genlock PLL
MK9173-15 ICSI

获取价格

Video Genlock PLL
MK9173-15CS08 ICSI

获取价格

Video Genlock PLL
MK9173-15CS08LFT IDT

获取价格

PLL Based Clock Driver, 9173 Series, 2 True Output(s), 0 Inverted Output(s), CMOS, PDSO8,
MK9173-15CS08T ICSI

获取价格

Video Genlock PLL
MK9-1A66B MEDER

获取价格

Reed Sensor Incorporated into a Hirschmann Connector
MK9-1A66C MEDER

获取价格

Reed Sensor Incorporated into a Hirschmann Connector