5秒后页面跳转
CY15B016Q-SXET PDF预览

CY15B016Q-SXET

更新时间: 2024-10-29 17:00:39
品牌 Logo 应用领域
英飞凌 - INFINEON 存储
页数 文件大小 规格书
21页 853K
描述
铁电存储器 (F-RAM)

CY15B016Q-SXET 数据手册

 浏览型号CY15B016Q-SXET的Datasheet PDF文件第4页浏览型号CY15B016Q-SXET的Datasheet PDF文件第5页浏览型号CY15B016Q-SXET的Datasheet PDF文件第6页浏览型号CY15B016Q-SXET的Datasheet PDF文件第8页浏览型号CY15B016Q-SXET的Datasheet PDF文件第9页浏览型号CY15B016Q-SXET的Datasheet PDF文件第10页 
CY15B016Q  
The two SPI modes are shown in Figure 4 and Figure 5. The  
status of the clock when the bus master is not transferring data is:  
WREN - Set Write Enable Latch  
The CY15B016Q will power up with writes disabled. The WREN  
command must be issued before any write operation. Sending  
the WREN opcode allows the user to issue subsequent opcodes  
for write operations. These include writing the Status Register  
(WRSR) and writing the memory (WRITE).  
SCK remains at 0 for Mode 0  
SCK remains at 1 for Mode 3  
The device detects the SPI mode from the status of the SCK pin  
when the device is selected by bringing the CS pin LOW. If the  
SCK pin is LOW when the device is selected, SPI Mode 0 is  
assumed and if the SCK pin is HIGH, it works in SPI Mode 3.  
Sending the WREN opcode causes the internal Write Enable  
Latch to be set. A flag bit in the Status Register, called WEL,  
indicates the state of the latch. WEL = ‘1’ indicates that writes are  
permitted. Attempting to write the WEL bit in the Status Register  
has no effect on the state of this bit – only the WREN opcode can  
set this bit. The WEL bit will be automatically cleared on the rising  
edge of CS following a WRDI, a WRSR, or a WRITE operation.  
This prevents further writes to the Status Register or the F-RAM  
array without another WREN command. Figure 6 illustrates the  
WREN command bus configuration.  
Figure 4. SPI Mode 0  
CS  
0
1
2
3
4
5
6
7
SCK  
SI  
Figure 6. WREN Bus Configuration  
7
6
5
4
3
2
1
0
MSB  
LSB  
CS  
0
1
2
3
4
5
6
7
SCK  
SI  
Figure 5. SPI Mode 3  
0
0
0
0
0
1
1
0
CS  
0
1
2
3
4
5
6
7
HI-Z  
SO  
SCK  
WRDI - Reset Write Enable Latch  
The WRDI command disables all write activity by clearing the  
Write Enable Latch. The user can verify that writes are disabled  
by reading the WEL bit in the Status Register and verifying that  
WEL is equal to ‘0’. Figure 7 illustrates the WRDI command bus  
configuration.  
SI  
7
6
5
4
3
2
1
0
MSB  
LSB  
Power Up to First Access  
The CY15B016Q is not accessible for a tPU time after power up.  
Users must comply with the timing parameter tPU, which is the  
minimum time from VDD (min) to the first CS LOW.  
Figure 7. WRDI Bus Configuration  
CS  
Command Structure  
0
1
2
3
4
5
6
7
There are six commands, called opcodes, that can be issued by  
the bus master to the CY15B016Q. They are listed in Table 1.  
These opcodes control the functions performed by the memory.  
SCK  
SI  
0
0
0
0
0
0
1
0
Table 1. Opcode commands  
Name  
WREN  
Description  
Set write enable latch  
Write disable  
Opcode  
0000 0110b  
0000 0100b  
0000 0101b  
0000 0001b  
0000 0011b  
0000 0010b  
HI-Z  
SO  
WRDI  
RDSR  
WRSR  
READ  
WRITE  
Read Status Register  
Write Status Register  
Read memory data  
Write memory data  
Document Number: 002-10555 Rev. *C  
Page 6 of 20  

与CY15B016Q-SXET相关器件

型号 品牌 获取价格 描述 数据表
CY15B064J CYPRESS

获取价格

64-Kbit (8K × 8) Serial (I2C) Automotive F-R
CY15B064J-SXA INFINEON

获取价格

铁电存储器 (F-RAM)
CY15B064J-SXAT INFINEON

获取价格

铁电存储器 (F-RAM)
CY15B064J-SXE CYPRESS

获取价格

Memory Circuit, 8KX8, CMOS, PDSO8, SOIC-8
CY15B064J-SXE INFINEON

获取价格

铁电存储器 (F-RAM)
CY15B064J-SXET CYPRESS

获取价格

64-Kbit (8K × 8) Serial (I2C) Automotive F-R
CY15B064J-SXET INFINEON

获取价格

铁电存储器 (F-RAM)
CY15B064Q CYPRESS

获取价格

64-Kbit (8K × 8) Serial (SPI) Automotive F-R
CY15B064Q-SXA INFINEON

获取价格

铁电存储器 (F-RAM)
CY15B064Q-SXAT INFINEON

获取价格

铁电存储器 (F-RAM)