SKAI 90 A2 GD06-W12CI
Characteristics
Symbol Conditions
Electrical Data
min.
typ.
max.
Unit
Visol
VCC
DC, t = 1 s
DC supply voltage
3000
350
V
V
450
rms @ rated conditions: dV/dt = 10l/
min, 50% Glykol/ 50% H20, fsw = 4kHz,
Inom
V
CC = 350V, Vout = 200V, fout = 50 Hz,
300
A
cos(phi) = 0.85, M = 0.93,
coolant = 65 °C, Tair = 65 °C
T
HV SKAI 2
fsw
CDC
Cy
RF
RBL
Switching frequency
DC Bus Capacitance
EMI Capacitor; DC to enclosure
DC+ to enclosure, DC- to enclosure
DC+ to DC-
1
0.9
15
1.25
kHz
mF
µF
M
M
0.66
1.13
1
Three-phase IGBT inverter
Mechanical Data
Weight
Height
Width
Length
SKAI 90 A2 GD06-W12CI
15
109
244
475
14
kg
Target Data
mm
mm
mm
Nm
Features
• Optimized for HEV and EV
• high power density
• high overload capability
• Compact integration in IP67 Enclosure:
V, I, T sensors
Mt
AC / DC terminals (M8 screw)
13
15
Cover of terminal box (M5x16
flat-head-screw)
Mc
3.5
4
4.5
Nm
Mcg
Me
AC / DC cable glands (recommended)
10
Nm
Nm
Integrated Controller
Gate driver with protection features
IGBT‘s + CAL Diodes
Fully programmable digital
signalprocessor
Assembly of
M8 screw
20
14
15
enclosure;
thread (l): > 15mm
M6 screw
Nm
Nm
Mgnd
Ground connection
13
14
EMI filters
Hydraulical Data
Liquid cooling
Pressure drop@ 10l/min,
coolant = 25°C
Operating pressure
DC link capacitor
dp
p
100
mbar
bar
T
Typical Applications*
2
• commercial application vehicle
• hybrid vehicle
Power dissipation to coolant; rated
conditions
P
1.9
kW
• battery driven vehicle
Environmental Data
Tstg
Tno
storage temperature
Non operating temperature range
Operating range, derating for
-40
-40
85
105
°C
°C
No. 14282006
Tair
-40
-40
105
75
°C
°C
T
air > 85°C
Operating range, derating for
Tcoolant
IP
T
coolant > 65°C
Enclosure protection level
IP67
With external connector protection
IP6K9K
Altitude
V
CC =450 V
5000
m
HV SKAI 2