5秒后页面跳转
MCAA60W-A PDF预览

MCAA60W-A

更新时间: 2024-11-21 20:04:19
品牌 Logo 应用领域
SLPOWER /
页数 文件大小 规格书
7页 711K
描述
Power Supply Module

MCAA60W-A 技术参数

是否Rohs认证: 不符合生命周期:Obsolete
包装说明:,Reach Compliance Code:unknown
Factory Lead Time:15 weeks风险等级:5.78
Base Number Matches:1

MCAA60W-A 数据手册

 浏览型号MCAA60W-A的Datasheet PDF文件第2页浏览型号MCAA60W-A的Datasheet PDF文件第3页浏览型号MCAA60W-A的Datasheet PDF文件第4页浏览型号MCAA60W-A的Datasheet PDF文件第5页浏览型号MCAA60W-A的Datasheet PDF文件第6页浏览型号MCAA60W-A的Datasheet PDF文件第7页 
Commercial/Medical International + Linears  
Medical  
Commercial  
FEATURES  
• World-wide ac input ranges and safety standards  
• Industry standard packages  
• Medical leakage current does not exceed 10 µA  
• MTBF 200,000+ hours per Mil Handbk 217D (most units)  
• All electrolytic caps rated at 105ºC  
Transformer insulation meets Class F (155ºC)  
• Exceed FCC and CISPR22, Class B conducted emissions  
• Commercial UL/CSA TUV/IEC approved—68 models to  
UL1950; CSA C22.2 No. 950 L3; TUV certified to EN60950  
• Burn-in with cycling; 3-year warranty  
• Capacitors have highest CV & ripple current ratings  
marked to LVD  
• Medical Approved to UL2601-1, IEC60601-1 and  
CSA601.1  
SPECIFICATIONS:  
Ac Input  
Remote Sensing  
Provided on all models; open sense lead protection built-in  
(except HA series).  
100, 120 and 240 Vac: +10%, -13%; 215 Vac: +12%, -11  
%; 47 to 63Hz. Tolerance for 230 Vac operation is +15%,  
-10%. Derate output current 10% for 50 Hz operation.  
Stability  
0.05% for 24 hours after warmup.  
Dc Output  
See voltage rating chart. Adjustment range 5% minimum  
except HA series.  
Temperature Rating  
0 to 50°C full rated, derated linearly to 40% at 70°C.  
Line Regulation  
0.05% for a 10% change.  
Temperature Coefficient  
0.01%/°C maximum.  
Load Regulation  
0.05% for a 50% load change.  
Efficiency  
5 V units: 45%; 12 and 15 V units: 55%; 20 and 24 V units: 60%.  
Output Ripple  
3 mV +0.05% of output voltage, peak to peak maximum.  
All “3-terminal regulator” outputs: 3 mV +0.2% peak to  
peak maximum.  
Logic Inhibit and Current-Share  
F & G models.  
Medical Stock andVibration  
Per Mil-Std-810D, Method 514.3, Category 1, Procedure 1.  
Per Mil-Std-810D, Method 516.3, Procedure III.  
Transient Response  
<50 microseconds for 50% load change.  
Short Circuit Protection  
Automatic current limit/foldback.  
Storage  
-40 to +85 °C.  
Overvoltage Protection  
Built-in on all 5 V models, set at 6.2 V 0.4 V. Other models  
use optional overvoltage protection.  
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033  
800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com  
116  

与MCAA60W-A相关器件

型号 品牌 获取价格 描述 数据表
MCAC012N06H MCC

获取价格

Tape&Reel:5Kpcs/Reel;
MCAC014N10Y MCC

获取价格

Tape&Reel:5Kpcs/Reel;
MCAC100N03Y MCC

获取价格

Tape&Reel:5Kpcs/Reel;
MCAC100N04 MCC

获取价格

Tape&Reel:5Kpcs/Reel;
MCAC100N08Y MCC

获取价格

Tape&Reel:5Kpcs/Reel;
MCAC100N08YA MCC

获取价格

Tape&Reel:5Kpcs/Reel;
MCAC100N10YHE3 MCC

获取价格

Tape&Reel:5Kpcs/Reel;
MCAC10H03A MCC

获取价格

Tape&Reel:5Kpcs/Reel;
MCAC115P02 MCC

获取价格

Tape&Reel:5Kpcs/Reel;
MCAC120N04YHE3 MCC

获取价格

Tape&Reel:5Kpcs/Reel;