IDP-2S Series
I&Q NETWORKS
20 to 500 MHz / Two I&Q Phase Detectors with Common LO / Hermetic Package
PRINCIPAL SPECIFICATIONS
GENERAL SPECIFICATIONS
†Bandwidth
MHz
RF and LO Input Characteristics
Model
Number
RF/LO Center
Frequency, f0
Impedance:
50 W nom.
IDP-2S-***B
20 to 500 MHz
10% of fo
VSWR:
1.5:1 max.
†RF and video bandwidths are typically much greater than specified.
RF Power Level:
LO Power Level
0 dBm nom.
+14 dBm nom.
*** Insert center frequency in MHz.
I & Q Output Characteristics
Video Bandwidth: DC to †50 MHz nom.
Output Impedance: 50 W nom.
Conversion Loss
Meri-PacÔ S-Package Outline
(RF to I or Q):
10 dB typ.
12 dB max.
IF Balance
Phase:
0 ± 5° max.
(I1 - I2 or Q1 - Q2)
90 ± 5° max.
(I1 - Q1 or I2 - Q2)
Amplitude:
0.5 dB typ.,1 dB max.
0.35 oz (10 g)
Weight, nominal:
Operating Temp:
-- 55° to +85°C
AVAILABLE OPTIONS
Phase Balance:
90° ± 2° max.
0.5 dB max.
NOTES: 1. Tolerance on 3 place decimals ±.010(.25 except as noted.
2. Dimensions in inches over millimeters.
Amplitude Balance:
Wider Bandwidth:
3. Lead dimensions apply only at body.
4. All unmarked pins are case ground.
Customized units
23Feb96
General Notes:
1. Dual I & Q networks are integrated devices that produce two pairs of quadrature-phased, equal amplitude
signals when fed by two IF signals and an LO signal as shown in the schematic above.
2. Merrimac’s IDP-2S series combines two matched circuits in one package. Both lumped and distributed
circuit technologies are used to minimize size and weight while maintaining excellent overall performance.
3. Merrimac’s I & Q networks comply with the relevant sections of MIL-M-28837 and may be screened for
compliance with additional specifications for military and space applications requiring the highest reliability.
ForfurtherinformationcontactMERRIMAC/41FairfieldPl.,WestCaldwell,NJ,07006/ 973 575-1300/FAX973-575-0531