Current Transducer HXS 10-NP/SP3
IPN = 10 A
For the electronic measurement of currents : DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
DUAL PHASE
All Data are given with a RL = 10 kW
Electrical data
Primarynominal
r.m.s. current
IPN (A)
Primary current
measuring range
IP (A)
Type
Features
· Hall effect measuring principle
· Multirange current transducer
through PCB pattern lay-out
· Galvanic isolation between primary
and secondary circuit
· Isolation test voltage 3500V
· Low power consumption
· Extremely low profile, < 11mm
· Single power supply +5V
· Fixed offset & gain
Serial
± 10
Parallel
± 20
Serial
± 30
Parallel
± 60
HXS 10-NP/SP3
VOUT
VREF
Analog output voltage @ IP
IP = 0
Internal Reference 1) - Output voltage
VREF Output impedance
VREF Load impedance
Output load resistance
Output impedance
Max. output capacitive load
Supply voltage (± 5 %)
VREF ±(0.625·IP/IPN) V
VREF ± 0.0125
2.5 ± 0.025
V
V
W
typ. 200
³ 200
³ 2
< 10
< 1
5
kW
kW
W
RL
ROUT
CL
VC
· Insulated plastic case recognized
according to UL 94-V0.
µF
V
IC
Current consumption @ VC = 5 V
22
mA
Special Feature
Accuracy - Dynamic performance data
· Two separate primary windings for
dual phase measurement
X
e
Accuracy 2) @ IPN , TA = 25°C
Linearity error 0.. IPN
.. 3 x IPN
£ ± 1
£ ± 0.5
£ ± 1
£ ± 0.4
£ ± 0.01
£ ± 0.2
% of IPN
% of IPN
% of IPN
mV/K
%/K
mV/K
L
Advantages
TCVOUT Thermal drift of VOUT @ IP = 0
TCVREF Thermal drift of VREF
TCVOUT /VREF Thermal drift of VOUT / VREF @ IP = 0
· Small size and space saving
· Only one design for wide current
ratings range
· High immunity to external
interference.
TCe Thermal drift of the gain
£ ± 0.05%ofreading/K
G
VOM
tra
tr
Residual voltage@ IP = 0, after an overload of 3 x IPN DC < ± 0.7
Reaction time @ 10 % of IPN
Response time @ 90 % of IPN
% of IPN
µs
< 3
< 5
· Internal & external reference
µs
di/dt di/dt accurately followed
> 50
< 20
< 40
DC .. 50
A/µs
mVpp
mVpp
kHz
Applications
Vno
Output noise(DC ..10 kHz)
(DC .. 1 MHz)
Frequency bandwidth (-3 dB) 3)
· AC variable speed drives
· Static converters for DC motor drives
· Battery supplied applications
· Uninterruptible Power Supplies
(UPS)
f
General data
TA
TS
m
Ambient operating temperature
Ambient storage temperature
Mass
- 40 .. + 85
- 40 .. + 85
10
°C
°C
g
· Switched Mode Power Supplies
(SMPS)
· Power supplies for welding
applications.
Standards
EN 50178: 1997
Notes : 1) It is possible to overdrive VREF with an external reference voltage
between 2 - 2.8 V providing its ability to sink or source approximately
2.5 mA.
ApplicationDomain
2) Excluding offset and hysteresis.
· Industrial
3) Small signal only to avoid excessive heatings of the magnetic core.
Page 1/3
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
061004/5
www.lem.com