74AUP2G04
Absolute Maximum Ratings (Notes 6,7) (@TA = +25°C, unless otherwise specified.)
Symbol
ESD HBM
ESD CDM
ESD MM
VCC
Description
Human Body Model ESD Protection
Rating
Unit
kV
kV
V
2
Charged Device Model ESD Protection
Machine Model ESD Protection
Supply Voltage Range
1
200
-0.5 to +4.6
V
Input Voltage Range
-0.5 to +4.6
V
VI
Voltage applied to output in high or low state
Input Clamp Current VI<0
V
Vo
-0.5 to VCC +0.5
-50
-50
mA
mA
mA
mA
mA
°C
IIK
IOK
IO
Output Clamp Current (VO < 0 )
±20
Continuous Output Current (VO = 0 to VCC
Continuous Current through VCC
Continuous Current through GND
Operating Junction Temperature
Storage Temperature
)
50
ICC
-50
IGND
TJ
-40 to +150
-65 to +150
°C
TSTG
Notes:
6. Stresses beyond the absolute maximum may result in immediate failure or reduced reliability. These are stress values and device
operation should be within recommend values.
7. Forcing the maximum allowed voltage could cause a condition exceeding the maximum current or conversely forcing the maximum current could
cause a condition exceeding the maximum voltage. The ratings of both current and voltage must be maintained within the controlled range..
Recommended Operating Conditions (Note 8) (@TA = +25°C, unless otherwise specified.)
Symbol
VCC
VI
Parameter
Min
0.8
0
Max
3.6
3.6
VCC
-20
-1.1
-1.7
-1.9
-3.1
-4
Unit
V
Operating Voltage
Input Voltage
—
V
Output Voltage
0
V
VO
—
—
—
—
—
—
—
—
—
—
—
—
µA
VCC = 0.8V
VCC = 1.1V
VCC = 1.4V
VCC = 1.65V
VCC = 2.3V
VCC = 3.0V
VCC = 0.8V
VCC = 1.1V
VCC = 1.4V
VCC = 1.65V
VCC = 2.3V
VCC = 3.0V
High-Level Output Current
IOH
mA
µA
20
1.1
1.7
1.9
3.1
4
Low-Level Output Current
IOL
mA
∆t/∆V
Input Transition Rise or Fall Rate
Operating Free-Air Temperature
—
200
125
ns/V
°C
V
CC = 0.8V to 3.6V
—
-40
TA
Note:
8. Unused inputs should be held at VCC or Ground.