Ordering number : ENN7085A
TND303S
ExPD (Excellent Power Device)
TND303S
General Purpose Driver for PDP Sustain Pulse Drive, DC / AC Motor
Drive, Switching Power Supply, DC / DC Converter Applications
Preliminary
Features
Package Dimensions
unit : mm
•
Inverter buffer.
•
Monolithic structure(High voltage CMOS process
adopted).
2199
[TND303S]
•
•
•
•
•
Withstand voltage of 25V is assured.
Wide range of operating voltage : 4.5V to 25V.
Peak outpout current : 2A.
Fast switching time(25ns typical at 1000pF load).
Fully compatible input to TTL/CMOS.
8
5
1 : NC
(V =not more than 2.6V, at V =4.5 to 25V)
IH DD
2 : IN A
3 : GND
4 : IN B
5 : OUT B
6 : VDD
7 : OUT A
8 : NC
1
4
0.2
5.0
Specifications
1.27
0.595
0.43
SANYO : SOP8
Absolute Maximum Ratings at Ta=25°C
Parameter
Symbol
Conditions
Ratings
Unit
Supply Voltage
Input Voltage
V
0 to 25
V
V
DD
V
GND--0.3 to V +0.3
DD
IN
Allowable Power Dissipation
Junction Temperature
Storage Temperature
P
max
0.3
--55 to +150
--55 to +150
W
°C
°C
D
Tj
Tstg
Recommended Operating Conditions at Ta=25°C
Parameter
Operating Supply Voltage
Operating Temperature
Symbol
Conditions
Ratings
Unit
V
V
DD
Topr
4.5 to 25
--40 to +125
°C
Electrical Characteristics (AC Characteristics) at Ta=25°C, V =18V, V =5V
DD
IN
Ratings
Parameter
Turn-On Rise Time
Symbol
Conditions
Unit
min
typ
max
t
r
C =1000pF
20
25
30
45
35
40
45
60
ns
ns
ns
ns
L
Turn-Off Fall Time
t
f
C =1000pF
L
t
t
1
C =1000pF
L
D
Delay Time
2
D
C =1000pF
L
Any and all SANYO products described or contained herein do not have specifications that can handle
applications that require extremely high levels of reliability, such as life-support systems, aircraft's
control systems, or other applications whose failure can be reasonably expected to result in serious
physical and/or material damage. Consult with your SANYO representative nearest you before using
any SANYO products described or contained herein in such applications.
SANYO assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or other
parameters) listed in products specifications of any and all SANYO products described or contained
herein.
SANYO Electric Co.,Ltd. Sem iconductor Com pany
TOKYO OFFICE Tokyo Bldg., 1-10, 1 Chome, Ueno, Taito-ku, TOKYO, 110-8534 JAPAN
62003 TS IM TA-100712 / O0501 TS IM TA-3492 No.7085-1/4