S108T01/S108T02/S208T01/S208T02
Low Profile Type
Solid State Relays
S108T01/S108T02
S208T01/S208T02
■ Features
■ Outline Dimensions
(Unit : mm)
1. Low profile type (height : 16mm)
23±0.2
7±0.2
Model No.
S108T01
S108T02
S208T01
S208T02
2. Built-in zero-cross circuit (S108T02/S208T02)
3. RMS ON-state current IT : MAX. 8Arms
4. Approved by TÜV, No. R9750791 (S208TY1/S208TY2)
Input-Output : Basic Insulation
8A 125VAC
8A 265VAC
3±0.2
Common to pin No.2
R3.8±0.2
■ Applications
Common to pin No.2
0.5±0.2
6.4±0.2
φ3.7±0.2
1. Programmable controllers
2. Air conditioners
3. Copiers
Epoxy resin
S 1 0 8 T 0 1
8A125VAC
4. Automatic vending machines
Lot No.
(DIN Standard)
★
+ −
±0.2
■ Model line-ups
3-1.2
±0.2
1.6
(3.5)
±0.3
3-1.4
4-0.8
0.4±0.1
For 100V lines
S108T01
S108T02
For 200V lines
S208T01
S208T02
±0.2
±0.3
No zero-cross circuit
Built-in zero-cross circuit
1.8
(1.8)
1
2
3
4
(3.8)
(2.54)
(5.08) (10.16)
■ Absolute Maximum Ratings
(Ta=25°C)
Parameter
Symbol
Rating
Unit
mA
V
Arms
A
Internal connection diagram
S108T01/S208T01 S108T02/S208T02
Forward current
Reverse voltage
IF
VR
IT
50
6
*18
RMS ON-state current
*2 Peak one cycle surge current
Isurge
80
S108T01
Repetitive
400
S108T02
peak OFF-
V
VDRM
VDSM
S208T01
state voltage
600
400
600
1
2
3
4
1
2
3 4
S208T02
Z.C. : Zero-cross circuit
S108T01
Non-repetitive
S108T02
1
2
3
4
1
Output (Triac T1)
Output (Triac T2)
Input (+)
Output (Triac T1)
Output (Triac T2)
Input (+)
Input (−)
2
peak OFF-
V
3
S208T01
state voltage
4
Input (−)
S208T02
Critical rate of rise of ON-state current
Operating frequency
Operating temperature
Storage temperature
*3 Isolation voltage
★ : Do not allow external connection.
❈ ( ) : Typical dimensions
50
45 to 65
−25 to +100
−30 to +125
3.0
A/µs
Hz
dIT/dt
f
Topr
Tstg
Viso
Tsol
°C
°C
kVrms
°C
*4 Soldering temperature
260
*1 Refer to Fig.2, Fig.3
*2 60Hz sine wave, start at Tj=25°C
*3 Isolation voltage measuring method
(1) Dielectric withstand voltage tester with zero cross circuit shall be used.
(2) The applied voltage waveform shall be sine wave.
(3) Voltage shall be applied between input and output.
(Input and output terminals shall be shorted respectively.)
(4) AC 60Hz, 1min, 40 to 60%RH.
*4 For 10s
Notice
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP
devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
Internet Internet address for Electronic Components Group http://www.sharp.co.jp/ecg/