RGP30A THRU RGP30M
3.0 AMPS. Glass Passivated Junction Fast Recovery Rectifiers
Voltage Range
50 to 1000 Volts
Current
3.0 Amperes
DO-201AD
Features
ꢀ
High temperature metallurgically bonded constructed
Plastic material used carries Underwriters Laboratory
ꢀ
Classification 94V-0
ꢀ
ꢀ
Glass passivated cavity-free junction
Capable of meeting environmental standards of
MIL-S-19500
ꢀ
ꢀ
ꢀ
3.0 ampere operation at TA=55oC with no thermal runaway
Typical IR less than 0.2 uA
High temperature soldering guaranteed:
350oC / 10 seconds, 0.375”(9.5mm) lead length, 5 lbs.,
(2.3kg) tension
ꢀ
Fast switching for high efficiency
Mechanical Data
ꢀ
Case: JEDEC DO-201AD molded plastic over glass body
Lead: Plated Axial leads, solderable per MIL-STD-750,
Method 2026
ꢀ
ꢀ
ꢀ
ꢀ
Polarity: Color band denotes cathode end
Mounting position: Any
Weight: 0.048 ounce, 1.28 grams
Dimensions in inches and (millimeters)
Maximum Ratings and Electrical Characteristics
Rating at 25℃ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%
Symbol RGP RGP RGP RGP RGP RGP RGP
Type Number
Units
30A 30B 30D 30G 30J 30K 30M
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
VRRM
VRMS
VDC
50 100 200 400 600 800 1000
V
V
V
35
70 140 280 420 560 700
Maximum DC Blocking Voltage
50 100 200 400 600 800 1000
Maximum Average Forward Rectified
Current .375” (9.5mm) Lead Length
@ TA = 55℃
I(AV)
3.0
A
Peak Forward Surge Current, 8.3 ms Single
Half Sine-wave Superimposed on Rated
Load (JEDEC method )
Maximum Instantaneous Forward Voltage
@ 3.0A
IFSM
125
1.3
A
V
VF
IR
Maximum DC Reverse Current@ TA=25℃
at Rated DC Blocking Voltage @TA=125℃
5.0
100
uA
uA
Maximum Reverse Recovery Time ( Note 1 )
TJ=25℃
Trr
150
250
500
nS
Typical Junction Capacitance ( Note 2 )
Typical Thermal Resistance (Note 3)
Operating & Storage Temperature Range
Cj
40
30
pF
℃/W
℃
RθJA
TJ , TSTG
-65 to + 175
Notes: 1. Reverse Recovery Test Conditions: IF=0.5A, IR=1.0A Recover to 0.25A.
2. Measured at 1.0 MHz and Applied Reverse Voltage of 4.0 Volts.
3. Mount on Cu-Pad Size 16mm x 16mm on P.C.B.
- 580 -