SPECIFICATION
MODEL
MPS-65-3.3 MPS-65-5
MPS-65-7.5 MPS-65-12 MPS-65-13.5 MPS-65-15 MPS-65-24 MPS-65-27 MPS-65-48
DC�VOLTAGE
3.3V
5V
7.5V
8A
12V
13.5V
4.7A
15V
24V
27V
48V
RATED�CURRENT
CURRENT�RANGE
RATED�POWER
12A
12A
5.2A
4.2A
2.7A
2.4A
1.35A
0�~�1.5A
64.8W
0�~�15.2A
39.6W
0�~�13.8A
60W
0�~�9.6A
60W
0�~�6A
62.4W
0�~�5.4A
63.5W
0�~�4.8A
63W
0�~�3A
64.8W
0�~�2.7A
64.8W
OUTPUT�POWER�(max.)
72W(+3.3V:50W;+5V:69W)with�18CFM�min.�Forced�air�convection
OUTPUT
RIPPLE�&�NOISE�(max.) Note.2 80mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
VOLTAGE ADJ.�RANGE
2.97�~�3.63V 4.5�~�5.5V
6.75�~�8.25V 10.8�~�13.2V 12.2�~�14.85V 13.5�~�16.5V 21.6�~�26.4V 24.3�~�29.7V 43.2�~�52.8V
VOLTAGE�TOLERANCE Note.3 3.0%
3.0%
1.0%
3.0%
3.0%
1.0%
3.0%
2.0%
1.0%
2.0%
2.0%
1.0%
2.0%
2.0%
1.0%
2.0%
2.0%
1.0%
2.0%
2.0%
1.0%
2.0%
2.0%
1.0%
2.0%
LINE�REGULATION
LOAD�REGULATION
SETUP,�RISE�TIME
HOLD�TIME (Typ.)
1.0%
3.0%
800ms,�30ms/230VAC����������800ms,�30ms/115VAC�at�full�load
50ms/230VAC����������16ms/115VAC�at�full�load
90�~�264VAC����������127�~�370VDC
VOLTAGE�RANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
47�~�440Hz
66%
74%
76%
77%
78%
79%
80%
80%
80%
INPUT
1.6A/115VAC����������0.9A/230VAC
AC�CURRENT (Typ.)
INRUSH�CURRENT (Typ.)
COLD�START 15A/115VAC����������30A/230VAC
<0.3mA /�264VAC
LEAKAGE�CURRENT
73�~�105W�(3.3V:51�~�75W)(5V:70�~�105W) rated�output�power
Protection�type�: Hiccup�mode,�recovers�automatically�after�fault�condition�is�removed
OVER�LOAD
PROTECTION
3.8�~�4.46V 5.75�~�6.75V 8.63�~�10.1V 13.8�~�16.2V 15.5�~�18.2V 17.25�~�20.25V 27.6�~�32.4V 31�~�36.45V 55.2�~�64.8V
Protection�type�: Hiccup�mode,�recovers�automatically�after�fault�condition�is�removed
-10�~�+60 (Refer�to�output�load�derating�curve)
OVER�VOLTAGE
WORKING�TEMP.
20�~�90%�RH�non-condensing
WORKING�HUMIDITY
-20�~�+85 ,�10�~�95%�RH
ENVIRONMENT STORAGE�TEMP.,�HUMIDITY
TEMP.�COEFFICIENT
0.04%/ (0�~�50
10�~�500Hz,�2G�10min./1cycle,�Period�for�60min.each�along�X, Y,�Z�axes
VIBRATION
UL2601-1, TUV�EN60601-1,�IEC601-1 Approved
I/P-O/P:4KVAC�����I/P-FG:1.5KVAC�����O/P-FG:0.5KVAC
I/P-O/P,�I/P-FG:100M�Ohms/500VDC
SAFETY STANDARDS
WITHSTAND�VOLTAGE
SAFETY &
ISOLATION�RESISTANCE
EMC
(Note�4)
Compliance�to�EN55011�(CISPR11)�Class�B
EMI�CONDUCTION�&�RADIATION
HARMONIC�CURRENT
Compliance�to EN61000-3-2,-3
Compliance�to EN61000-4-2,3,4,5,6,8,11;�ENV50204,�EN60601-1-2�Medical�level,�criteria A
EMS�IMMUNITY
MTBF
359.7Khrs�min.������MIL-HDBK-217F�(25
127*76.2*42mm�(L*W*H)
)
OTHERS
NOTE
DIMENSION
PACKING
0.23Kg;�54pcs/14.6Kg/1.35CUFT
ꢣꢗꢈꢉꢇꢇꢈꢋꢆꢄꢆꢙꢃꢍꢃꢄꢅꢈꢭꢞꢮꢈꢅꢋꢃꢕꢁꢆꢇꢇꢡꢈꢙꢃꢀꢍꢁꢒꢀꢃꢟꢈꢆꢄꢃꢈꢙꢃꢆꢅꢌꢄꢃꢟꢈꢆꢍꢈꢯꢘꢖꢰꢉꢊꢈꢁꢀꢋꢌꢍꢱꢈꢄꢆꢍꢃꢟꢈꢇꢒꢆꢟꢈꢆꢀꢟꢈꢯꢩ ꢒꢢꢈꢆꢙꢠꢁꢃꢀꢍꢈꢍꢃꢙꢋꢃꢄꢆꢍꢌꢄꢃꢗ
ꢯꢗꢈꢲꢁꢋꢋꢇꢃꢈꢳꢈꢀꢒꢁꢅꢃꢈꢆꢄꢃꢈꢙꢃꢆꢅꢌꢄꢃꢟꢈꢆꢍꢈꢯꢖꢴꢫꢬꢈꢒꢢꢈꢠꢆꢀꢟꢓꢁꢟꢍꢝꢈꢠꢡꢈꢌꢅꢁꢀꢐꢈꢆꢈꢣꢯꢵꢈꢍꢓꢁꢅꢍꢃꢟꢈꢋꢆꢁꢄꢥꢓꢁꢄꢃꢈꢍꢃꢄꢙꢁꢀꢆꢍꢃꢟꢈꢓꢁꢍꢝꢈꢆꢈꢖꢗꢣꢌꢢꢈꢳꢈꢨꢶꢌꢢꢈꢋꢆꢄꢆꢇꢇꢃꢇꢈꢕꢆꢋꢆꢕꢁꢍꢒꢄꢗ
ꢘꢗꢈꢮꢒꢇꢃꢄꢆꢀꢕꢃꢈꢛꢈꢁꢀꢕꢇꢌꢟꢃꢅꢈꢅꢃꢍꢈꢌꢋꢈꢍꢒꢇꢃꢄꢆꢀꢕꢃꢱꢈꢇꢁꢀꢃꢈꢄꢃꢐꢌꢇꢆꢍꢁꢒꢀꢈꢆꢀꢟꢈꢇꢒꢆꢟꢈꢄꢃꢐꢌꢇꢆꢍꢁꢒꢀꢗ
ꢨꢗꢈꢮꢝꢃꢈꢋꢒꢓꢃꢄꢈꢅꢌꢋꢋꢇꢡꢈꢁꢅꢈꢕꢒꢀꢅꢁꢟꢃꢄꢃꢟꢈꢆꢈꢕꢒꢙꢋꢒꢀꢃꢀꢍꢈꢓꢝꢁꢕꢝꢈꢓꢁꢇꢇꢈꢠꢃꢈꢁꢀꢅꢍꢆꢇꢇꢃꢟꢈꢁꢀꢍꢒꢈꢆꢈꢢꢁꢀꢆꢇꢈꢃꢧꢌꢁꢋꢙꢃꢀꢍꢗꢈꢮꢝꢃꢈꢢꢁꢀꢆꢇꢈꢃꢧꢌꢁꢋꢙꢃꢀꢍꢈꢙꢌꢅꢍ ꢠꢃꢈꢄꢃꢥꢕꢒꢀꢢꢁꢄꢙꢃꢟꢈꢍꢝꢆꢍꢈꢁꢍꢈꢅꢍꢁꢇꢇꢈꢙꢃꢃꢍꢅ
ꢷꢴꢊꢈꢟꢁꢄꢃꢕꢍꢁꢂꢃꢅꢗ
ꢩꢗꢈꢴꢒꢌꢀꢍꢁꢀꢐꢈꢝꢒꢇꢃꢅꢈꢴꢣꢈꢆꢀꢟꢈꢴꢯꢈꢅꢝꢒꢌꢇꢟꢈꢠꢃꢈꢐꢄꢒꢌꢀꢟꢃꢟꢈꢢꢒꢄꢈꢷꢴꢸꢈꢋꢌꢄꢋꢒꢅꢃꢅꢗ
300 myleꢀ standiꢀh Blvd., Taunton, mA 02780
WWW.AsTRODYNE.COm
ph: 1-800-823-8082
Fax: 508-823-8181