Bourns® Model P500-G and P850-G Series
TBU® HSPs are not recommended for POTS
applications. This series is suited for
Features
■ Extremely high speed performance
■ Blocks high voltages and currents
■ Two TBU® protectors in one small package
■ Simple, superior circuit protection
■ Minimal PCB area
applications requiring a dual bidirectional device
where 50 ohms of series resistance is acceptable.
For new SLIC applications, we recommend that
customers evaluate our TBU-PL Series.
■ RoHS compliant*, UL Recognized
P500-G and P850-G Series Dual TBU® High-Speed Protectors
®
Transient Blocking Units - TBU Devices
Agency Approval
UL recognized component File # E315805.
®
®
Bourns Model P500-G and P850-G TBU products are dual
high-speed bidirectional protection components, constructed
using MOSFET semiconductor technology, designed to protect
against faults caused by short circuits, AC power cross,
induction and lightning surges.
Industry Standards
Description
Model
P500-G
P850-G
P850-G
Port Type 2, 4
Port Type 3, 5
K.20, K.20E, K.21, K.21E, K.45
®
The TBU high speed protector, triggering as a function of
Telcordia
ITU-T
GR-1089
the MOSFET, blocks surges and provides an effective barrier
behind which sensitive electronics are not exposed to large
®
voltages or currents during surge events. The TBU device is
provided in a surface mount DFN package and meets industry
standard requirements such as RoHS and Pb Free solder
reflow profiles.
Absolute Maximum Ratings (T
= 25 °C)
amb
Symbol
Parameter
Maximum protection voltage for impulse faults with rise time ≥ 1 µsec
Value
Unit
P500-Gxxx-WH
P850-Gxxx-WH
500
V
V
V
imp
850
P500-Gxxx-WH
300
425
Maximum protection voltage for continuous V
faults
V
rms
rms
P850-Gxxx-WH
T
T
Operating temperature range
Storage temperature range
-40 to +85
-65 to +150
°C
°C
op
stg
Electrical Characteristics (T
= 25 °C)
amb
Symbol
Parameter
Min.
Typ.
Max.
Unit
P500-G120-WH
100
200
100
200
Maximum current through the device that will not cause
current blocking
P500-G200-WH
P850-G120-WH
P850-G200-WH
I
I
I
mA
op
P500-G120-WH
P500-G200-WH
P850-G120-WH
P850-G200-WH
P500-G120-WH
P500-G200-WH
P850-G120-WH
P850-G200-WH
150
275
150
275
Typical current for the device to go from normal operating
state to protected state
mA
mA
trigger
out
200
400
200
400
55
2
Maximum current through the device
®
Ω
Ω
R
R
Series resistance of the TBU device
50
device
bal
®
Line-to line series resistance difference between two TBU devices
Maximum time for the device to go from normal operating
t
I
1
µs
mA
V
block
state to protected state
®
Current through the triggered TBU device with 50 Vdc circuit
0.7
22
quiescent
voltage
®
Voltage below which the triggered TBU device will transition to
V
reset
normal operating state
®
The P-G series TBU devices are bidirectional; specifications are valid in both directions.
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.