H HiTRON
2008/09/26
UNIVERSAL INPUT HARMONIC CORRECTION
RESONANT AC-DC OPEN FRAME TRIPLE OUTPUT 200 WATTS
INTERNAL SWITCHING POWER SUPPLIES HIRP200 SERIES
FEATURES:
ACCOMMODATE UNIVERSALAC SOURCES
5” x 3” COMPACT SIZE IN 1U HEIGHT
5V STAND-BY & 12V FAN OUTPUTS
RESONANT DESIGN CIRCUIT
MEET UNIVERSAL SAFETY STANDARDS
EMI MEET CISPR PUB. 22 & FCC CLASS A
CE MARKING COMPLIANCE
POWER DENSITY AS HIGH AS 9.95W/C.I.
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Connector: V-H connectors.
Output Wattage: Max. 200W.
Line Regulation: Typ. ±0.1%.
Load Regulation: VO1 & VO3 typ. ±1%.
VO2 typ. ± 3.0%.
Input Voltage: Typ. 90-264Vac with PFC.
Input Connector: V-M connector.
Input Frequency: 47-63Hz.
Inrush Current: Typ. 11.4-11.7Arms@230Vac.
Input Current: 1.95-2.16A @115Vac, 1.0-1.15A @230Vac.
Dielectric Withstand: Meet IEC 60950-1.
EMI: Meet CISPR PUB. 22 & FCC Class A.
Hold-up Time: Typ. 16-18mS @115Vac & 230Vac.
Power Fail Signal: Installed.
Noise & Ripple: Typ. 1.0% peak to peak.
OVP: Installed in VO1 & VO2 (Latch).
Adjustability: Available at VO1.
Remote ON/OFF: Installed.
DC OK Signal: Installed.
Power Factor & Harmonic Correction:
Meet IEC 61000-3-2, PF typ.0.95@ full load.
Leakage Current: Less than 0.75-0.79mA.
Overload Protection (OLP): Fully protected against
output overload and short circuit. Typical 115-130% at
115Vac.Consult the factory for the special OLP setting.
GENERAL SPECIFICATION
Efficiency: Typ. 87-92%.
Switching Frequency: 100-105K Hz.
Circuit Topology: ZVS circuit.
Transient Response:
Operating Temperature: 0 to +50°Cat full load with
specified air flow.
Storage Temperature: 0 to +85°C.
Temperature Coefficient: 0.05%/°C.
Cooling: 400LFM airflow is required to deliver the full
power. 200W.
+12V and +24V voltage returns within 1mS following
a 25% load change.
+48V voltage returns within 1.75mS following
a 25% load change.
Construction: PCB format.
Power Density: 9.95 Watts / Cubic Inch.
Safety Standard: UL 60950-1/EN 60950-1 Class I.
Note: (1)Due to requests in market and advances in technology, specifications subject to change without notification.
(2)All measurement are at nominal input, full load and +26°C unless otherwise specifications.