GT-25 SERIES 25W
Data Sheet
Switching Power Supplies
SWITCHING POWER SUPPLY, SINGLE OUTPUT:
25 WATTS, ENCLOSED, UNIVERSAL INPUT
ISO 9001
REGISTERED
1. NOTES:
DIMENSIONS ARE IN MM UNLESS SPECIFIED OTHERWISE.
2. ELECTRICAL SPECIFICATIONS:
INPUT VOLTAGE:
INPUT CURRENT:
85 VAC TO 264 VAC
0.35A @ 230V
47 HZ - 63 HZ
P/N :
INPUT FREQUENCY:
OUTPUT VOLTAGE / CURRENT:
MODEL:
S-25-5
OUTPUT:
GT-25-5
+5 VDC +/-2%, 5A
+12 VDC +/-1%, 2.1A
+15 VDC +/-1%, 1.7A
+24 VDC +/-1%, 1.1A
GT-25-12
GT-25-15
GT-25-24
S-25-12
S-25-15
S-25-24
OUTPUT CURRENT :
OUTPUT POWER (RATED):
OUTPUT RIPPLE (PEAK TO PEAK):
NO LOAD TO FULL LOAD, NO MINIMUM LOAD REQUIRED
25 WATTS MAX
50 mV (P-P) FOR 5V,
100 mV (P-P) FOR ALL OTHER OUTPUTS
+10, -5% OUTPUT
+ 5 % FOR OUTPUT
ADJUSTABILITY:
OUTPUT REGULATION (LINE):
LOAD REGULATION (LINE):
5V MODEL +/-1%, 0.5% FOR ALL OTHER OUTPUTS
TURN ON/ TURN OFF OVERSHOOT:
TURN-ON DELAY:
HOLD-UP TIME:
4% MAX 500uS MAX RECOVERY TIME FOR 25% STEP LOAD
1 SEC MAX
10 mSEC MIN AT NOMINAL INPUT 115 VAC AND FULL LOAD
15 A MAX AT COLD START FOR N.A. (30A FOR EURO)
75 % TYPICAL
INRUSH CURRENT:
EFFICIENCY:
SWITCHING FREQUENCY:
OVER-VOLTAGE PROTECTION:
100 KHZ TYPICAL
VOLTAGE LIMITED LESS 115% ~ 135% OF NOMINAL VOLTAGE
FOR MAIN OUTPUT
OVER-CURRENT / SHORT CIRCUIT:
OTHER PROTECTION:
SAFETY APPROVALS :
HICCUP WITH AUTO RECOVERY TO 1.1 - 1.3 IO
INPUT FUSING
UL1012, UL 60950 / 1950, CUL TO 22.2 # 234, 950, TUV TO EN 60950,
CE CLASS I
DIELECTRIC WITHSTAND VOLTAGE:
LEAKAGE CURRENT:
LINE SURGE:
3000VAC PRIMARY-SECONDARY; 1500 VAC PRIMARY- GROUND
< 0.75 mA @ 240 VAC
EN 61000-4-5 LEVEL 4
EMI:
COMPLIES WITH EN55022, 1 CLASS B AND
FCC PART 15 CLASS B WHEN TESTED WITH A RESISTIVE
LOAD, BOTH CONDUCTED AND RADIATED
CE MARK :
TESTED TO COMPLY WITH EN61000-3-2, EN61000-3-3 AND EN50082-1
INCLUDING EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5,
EN61000-4-6, EN61000-4-11 LEVEL 4, UNIT IS ELIGIBLE
FOR CE MARK.
ꢀ
( 201) 784- 1000
w w w. g l o b t ek. co m
Fax: 201-784-0111
1
Globtek, Inc. 186 Veterans Drive, Northvale, NJ 07647.
Tel.: 201-784-1000