DIN Rail Mount
DataSheet
• 6.2mm Din-Rail Mount (35 mm) SSR Assembly
• Ratings 24VDC @ 3.5A, 48VDC @ 100mA and 240VAC @ 2A
• UL & cUL recognized @ 40°C, 100K-Cycle Endurance Test (SSR Only)
• AC output SSR is UL rated for Pilot Duty @ 240VAC
• CE & RoHS Compliant
AC
DC
DRACN Series
• Yellow LED input status indicator
• 5 & 24 VDC Control
PRODUCT SELECTION
Control Voltage
3-12 VDC
3.5 A
DRA-CN024D05
DRA-CN024D24
100 mA
2 A
DRA-CN048D05
DRA-CN240A05
15-30 VDC
DRA-CN048D24
DRA-CN240A24
AVAILABLE OPTIONS
Load Voltage
Switching Mode
024D: 24 VDC, 3.5 A
048D: 48 VDC, 0.1 A
240A: 240 VAC, 2 A
Blank: Zero Cross
Turn-On (AC Output Only)
R: Random Turn On
(AC Output Only)
Series
DRA-CN
4
024D D
Assembly Input Voltage
05: 05 VDC
24: 24VDC
Required for valid part number
For options only and not required for valid part number
OUTPUT SPECIFICATIONS (1)
Description
Operating Voltage
Maximum Load Current @ 40°C (2)
Minimum Load Current [mA]
Maximum Blocking Voltage
DRA-CN024DXX
DRA-CN048DXX
DRA-CN240AXX
0-48 VDC
100 mA
1
0-24 VDC
3.5 A
24-250 VAC
2 A
70
600 VAC
1
60 VDC
300 mA (10 ms)
N.A.
30 VDC
9 A (10 ms)
N.A.
0.4
0.001
500
Maximum Surge Current [Apk]
120/115 A (16.6/20 ms)
285/260
Maximum I²t for fusing 50/60Hz (1/2 cycle) [A² sec]
Typical On-State Voltage Drop @ Rated Current (V)
Maximum Off-State Leakage Current @ Rated Voltage [mA]
Maximum PWM (Hz) (3)
Switch Configuration
1.0
0.001
500
1.1
4.0
N.A.
N.O.
N.O.
N.O.
(1)
INPUT SPECIFICATIONS for CN024
Description
DRA-CN024D05
DRA-CN024D24
Control Voltage Range
Minimum Turn-On Voltage
Must Turn-Off Voltage
Nominal Input Impedance
Typical Input Current
Typical Turn-On Time
Typical Turn-Off Time
3-12 VDC
3.0 VDC
15-30 VDC
15 VDC
1.0 VDC
500 Ohm
10 mA @ 5.0 VDC
120 μs
15 VDC
2.67K Ohm
7 mA @ 24 VDC
350 μs
120 μs
80 μs
FDE-07-01 REV. A
Do not forget to visit us at: www.crydom.com
Copyright © 2018 Crydom Inc. Specifications subject to change without notice.