1N6626 – 1N6631
Solid State Devices, Inc.
Series
14701 Firestone Blvd * La Mirada, Ca 90638
Phone: (562) 404-4474 * Fax: (562) 404-1773
ssdi@ssdi-power.com * www.ssdi-power.com
2.3 – 1.8 AMP
HYPER FAST RECOVERY
RECTIFIER
Designer’s Data Sheet
Part Number/Ordering Information1/
1N __ __ __
200 - 1200 VOLTS
2/
│
│
│
│
│
│
│
│
│
│
└
│
│
│
│
│
│
└
└
Screening
30 - 60 nsec
__ = Not screened
TX = TX Level
TXV = TXV Level
S = S Level
FEATURES:
Hyper Fast Recovery: 30 - 60 nsec maximum
PIV up to 1200 Volts
Low Reverse Leakage Current
Hermetically Sealed
Void Free Construction
Package Type
__ = Axial Leaded
SMS = Surface Mount Square Tab
Voltage/Family
6626 = 200V
6627 = 400V
6628 = 600V
6629 = 800V
6630 = 900V
For High Efficiency Applications
6631 = 1000V
6631A = 1100V
6631B = 1200V
Typical Weight: 0.75 g (Axial Leaded); 0.45 g (SMS)
TX, TXV, and Space Level Screening Available2/
QPL registered devices per MIL-PRF-19500/590 may be
available, contact factory
MAXIMUM RATINGS3/
SYM
VALUE
UNIT
1N6626
1N6627
1N6628
1N6629
1N6630
1N6631
1N6631A
1N6631B
200
400
600
800
900
1000
1100
1200
VRRM
VRWM
VR
Peak Repetitive Reverse Voltage and
DC Blocking Voltage
VDC
Average Rectified Forward Current4/
1N6626 - 6628
1N6629 - 6631
2.3
1.8
IO1
A
A
(Average current with a half sine wave including reverse voltage
amplitude equal to the magnitude of the full rated VRWM
)
1N6626 - 6630
1N6631
75
60
Peak Surge Current
IFSM
(tp = 8.3 ms Pulse, Half Sine Wave, Superimposed on IO, TA = 25oC)
Storage Temperature
Tstg
TJ
-65 to +175
+150
oC
oC
Maximum Operating Temperature
Junction to Lead, L = 0.375” (Axial Lead)
Junction to End Tab (Surface Mount)
RJL
RJE
22
6.5
Maximum Thermal Resistance
oC/W
NOTES:
Square Tab
Surface Mount
(SMS)
Axial Leaded (__)
1/ For ordering information, price, operating curves, and availability- Contact factory.
2/ Screening based on MIL-PRF-19500. Screening flows available on request.
3/ Unless otherwise specified, all electrical characteristics @ 25°C.
4/ Derate linearly 1.33 percent/°C for TL > +75°C (Axial Leaded); Derate linearly 2.5
percent/°C for TEC > +110°C (SMS).
NOTE: All specifications are subject to change without notification.
SCD's for these devices should be reviewed by SSDI prior to release.
DATA SHEET #: RC0179A
DOC