3000W True Sine Wave DC-AC Inverter with Solar Charger
TN-3000 series
Features :
True sine wave output (THD<3%)
High surge power up to 6000W
U.P.S. mode and energy saving mode (selectable)
High efficiency up to 92%
Power ON-OFF switch
Standby saving mode can be selectable
Front panel indicator for operation status
Thermostatically controlled cooling fan
Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp.
/ Output short / Input polarity reverse / Overload / AC circuit breaker
Application : Home appliance, power tools, office and portable
equipment, vehicle and yacht ...etc.
Built-in solar / AC charger
Optional monitoring software
3 years warranty
E13
SPECIFICATION
MODEL
TN-3000-112
TN-3000-124
TN-3000-148
TN-3000-212
TN-3000-224
TN-3000-248
RATED POWER (Typ.)
3000W
3000W
3000W
3000W
3000W
3000W
MAXIMUM OUTPUT POWER 3450W for 180 sec. / 4500W for 10 sec. / surge power 6000W for 30 cycles
Factory setting set at 110VAC
Factory setting set at 230VAC
AC VOLTAGE
100 / 110 / 115 / 120VAC selectable by setting button S.W
60 0.1Hz 50/60Hz selectable by setting button S.W
True sine wave (THD<3%) at rated input voltage
3%
200 / 220 / 230 / 240VAC selectable by setting button S.W
50 0.1Hz 50/60Hz selectable by setting button S.W
FREQUENCY
OUTPUT
WAVEFORM
AC REGULATION (Typ.)
TRANSFER TIME (Typ.)
SAVING MODE (Typ.)
FRONT PANEL INDICATOR
BAT. VOLTAGE
t<10ms inverter
Load 5W will be changed to standby mode
Battery voltage level, output load level, saving mode, fault and operation status
by pass
24V
48V
24V
48V
12V
12V
VOLTAGE RANGE
Note.5 10.5 ~ 15VDC
Note.3 300A
21 ~ 30VDC
150A
42 ~ 60VDC
75A
10.5 ~ 15VDC
300A
21 ~ 30VDC
150A
42 ~ 60VDC
75A
DC CURRENT (Typ.)
10W @ standby saving mode
INPUT
NO LOAD DISSIPATION (Typ.)
OFF MODE CURRENT DRAW
1mA
EFFICIENCY (Typ.)
BATTERY TYPES
FUSE
Note.1 88%
90%
91%
89%
91%
92%
Open & sealed Lead Acid
40A*12
40A*6
22.5V
21V
20A*6
45V
40A*12
11.3V
40A*6
22.5V
21V
20A*6
45V
BATTERY
INPUT
PROTECTION
11.3V
Note.5
BAT. LOW ALARM
10.5V
42V
10.5V
42V
BAT. LOW SHUTDOWN Note.5
REVERSE POLARITY
By internal fuse open
105
5
95
5
95
5
90
5
85
5
85
5
OVER TEMPERATURE
OUTPUT SHORT
Protection type : Shut down o/p voltage, re-power on to recover
Protection type : Shut down o/p voltage, re-power on to recover
105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec.
Protection type : Shut down o/p voltage, re-power on to recover
AC input: 40A, AC output receptacle:15A
OUTPUT
PROTECTION
OVER LOAD (Typ.)
CIRCUIT BREAKER
GFCI PROCTECTION
AC input: 20A, AC output receptacle: 15A
None
Optional (Only type F)
WORKING TEMP.
Note.2
0 ~ +40 @ 100% load ; 60 @ 50% load
20% ~ 90% RH non-condensing
-30 ~ +70 / -22 ~ +158oF, 10 ~ 95% RH
WORKING HUMIDITY
ENVIRONMENT
STORAGE TEMP., HUMIDITY
VIBRATION
10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
None
UL458 (only for "GFCI" receptacle-Type F )
None
SAFETY STANDARDS
EN60950-1
LVD
SAFETY &
EMC
Bat I/P - AC I/P:3.0KVAC Bat I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC
WITHSTAND VOLTAGE
Compliance to EN55022 class A, 72/ 245/ CEE, 95/ 54/ CE, E-Mark
Compliance to EN61000-4-2,3,4,5,6,8,11 ENV50204
EMI CONDUCTION&RADIATION Compliance to FCC class A
None
25A
EMS IMMUNITY
12A
6A
12A
6A
CHARGE CURRENT (Typ.)
25A
AC
CHARGER
28.5V
45V
57V
75V
28.5V
45V
57V
75V
CHARGE VOLTAGE
MAX OPEN CIRCUIT VOLTAGE 25V
CHARGE CURRENT (max.) 30A
Note.5 14.3V
Note.5 14.3V
14.3V
25V
SOLAR
CHARGER
28.5V
57V
28.5V
57V
CHARGE VOLTAGE
CONTROL WIRING
DIMENSION
14.3V
RJ11 -RS232 (Option)
OTHERS
NOTE
466.8*283.5*100mm (L*W*H)
12.9Kg; 1pcs/14Kg/1.98CUFT
PACKING
1.Efficiency is tested by 2100W, linear load at 13V, 26V, 52V input voltage.
2.Output derating capacity referenced by curve 1.
3.DC current is tested by 3000W, linear load at 12V, 24V, 48V input voltage.
4.All parameters not specified above are measured at rated load, 25 of ambient temperature.
5.The tolerance of each voltage value by models is:112/212 0.5V;124/224 1V;148/248
2V
File Name:TN-3000-SPEC 2010-04-09