The TBU-CX Series is obsolete and not
recommended for new designs.
The TBU-CA Series is the
Features
■ Superior circuit protection
■ Overcurrent and overvoltage protection
■ Blocks surges up to rated limits
■ High-speed performance
■ Small SMT package
recommended alternative - see data sheet
for specifications.
CX85
0075
■ RoHS compliant*
■ Agency recognition:
TBU-CX Series - TBU® High-Speed Protectors
General Information
The TBU-CX Series of Bourns TBU
Agency Approval
®
®
External Resistor
Description
products are low capacitance dual bidirec-
tional high-speed protection components,
constructed using MOSFET semiconductor
technology, and designed to protect against
faults caused by short circuits, AC power cross,
induction and lightning surges.
R
UL
File Number: E315805
Line In/
Line Out
Line Out/
Line In
®
The TBU high-speed protector placed in the system circuit will monitor the current with
the MOSFET detection circuit triggering to provide an effective barrier behind which
sensitive electronics will not be exposed to large voltages or currents during surge
®
events. The TBU device is provided in a surface mount DFN package and meets
industry standard requirements such as RoHS and Pb Free solder reflow profiles.
Absolute Maximum Ratings (@ T = 25 °C Unless Otherwise Noted)
A
Symbol
Parameter
Part Number
Value
Unit
TBU-CX025-VTC-WH
TBU-CX040-VTC-WH
TBU-CX050-VTC-WH
TBU-CX065-VTC-WH
TBU-CX085-VTC-WH
250
400
500
650
850
V
V
Peak impulse voltage withstand with duration less than 10 ms
V
imp
TBU-CX025-VTC-WH
TBU-CX040-VTC-WH
TBU-CX050-VTC-WH
TBU-CX065-VTC-WH
TBU-CX085-VTC-WH
100
200
250
300
425
Continuous A.C. RMS voltage
V
rms
T
T
T
Operating temperature range
Storage temperature range
Maximum Junction Temperature
HBM ESD Protection per IEC 61000-4-2
-40 to +125
-65 to +150
+125
°C
°C
°C
kV
op
stg
jmax
ESD
2
Electrical Characteristics (@ T = 25 °C Unless Otherwise Noted)
A
Symbol
Parameter
Part Number
Min.
Typ.
Max.
Unit
Current required for the device to go from operating state to
I
TBU-CXxxx-VTC-WH
500
750
1000
mA
trigger
protected state (R
= 0 ohm)
external
V
V
V
V
V
= 250 V I
(min.) = 500 mA TBU-CX025-VTC-WH
(min.) = 500 mA TBU-CX040-VTC-WH
(min.) = 500 mA TBU-CX050-VTC-WH
(min.) = 500 mA TBU-CX065-VTC-WH
(min.) = 500 mA TBU-CX085-VTC-WH
2.6
3.6
3.0
4.2
imp
imp
imp
imp
imp
trigger
trigger
trigger
trigger
trigger
Series resistance of
the TBU device
= 400 V I
= 500 V I
= 650 V I
= 850 V I
Ω
R
5.0
5.7
device
(R
= 0 ohm)
7.0
8.0
external
10.7
13.0
t
I
V
R
R
Time for the device to go from normal operating state to protected state
Current through the triggered TBU® device with 50 Vdc circuit voltage
Voltage below which the triggered TBU® device will transition to normal operating state
Junction to package pads - FR4 using recommended pad layout
1
1.00
20
µs
mA
V
°C/W
°C/W
block
Q
0.25
12
0.50
16
98
reset
th(j-l)
th(j-l)
2
2
Junction to package pads - FR4 using heat sink on board (6 cm ) (1 in )
40
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.