Features
Applications
■ Superior circuit protection
■ Overcurrent and overvoltage protection
■ Blocks surges up to rated limits
■ High speed performance
■ Small SMT package
■ Ethernet ports
■ Protection modules and dongles
■ Process control equipment
■ Test and measurement equipment
■ General electronics
T855
0074
■ RoHS compliant*
■ Agency recognition:
TBU-DT Series - TBU® High Speed Protectors
General Information
The TBU-DT Series of Bourns® TBU® (Transient Blocking Unit) products are very low
capacitance dual unidirectional high speed surge protection components designed to
protect against faults caused by short circuits, AC power cross, induction and lightning
surges.
Line Side
Line Side
Load Side
Load Side
1
2
The TBU-DT series is a unidirectional TBU® device; the TBU® protector will trip in less
than 1 μs when the current reaches the maximum value in one direction only, that is when
Pin 1 is positive in voltage with respect to Pin 2, and Pin 4 is positive with respect to Pin 3.
No current limiting exists in the opposite polarity, and the TBU® device appears as resis-
tive in nature. The reverse current should not exceed the maximum trip current level of
the TBU® device. An external diode may be used to prevent reverse current in DC biased
applications.
4
3
TBU® Device
The TBU® protector blocks surges and provides an effective barrier behind which sensi-
tive electronics will not be exposed to large voltages or currents during surge events.
After the surge, the TBU® device resets when the voltage across the TBU® device falls to
the V
level. The TBU® device will automatically reset on lines which have no DC bias
Agency Approval
reset
or have DC bias below Vreset (such as unpowered signal lines).
Description
File Number: E315805
The TBU® device is provided in a surface mount DFN package and meets industry
standard requirements such as RoHS and Pb Free solder reflow profiles.
UL
Absolute Maximum Ratings (@ T = 25 °C Unless Otherwise Noted)
A
Symbol
Parameter
Part Number
Value
650
850
300
425
Unit
TBU-DT065-xxx-WH
TBU-DT085-xxx-WH
TBU-DT065-xxx-WH
TBU-DT085-xxx-WH
V
Peak impulse voltage withstand with duration less than 10 ms
V
V
imp
rms
V
Continuous A.C. RMS voltage
T
T
Operating temperature range
Storage temperature range
-40 to +85
-65 to +150
°C
°C
op
stg
Electrical Characteristics (@ T = 25 °C Unless Otherwise Noted)
A
Symbol
Parameter
Part Number
Min.
Typ.
150
300
450
750
8.5
5.6
4.6
4.0
Max.
200
400
600
1000
10.0
6.6
Unit
TBU-DTxxx-100-WH
TBU-DTxxx-200-WH
TBU-DTxxx-300-WH
TBU-DTxxx-500-WH
100
200
300
500
Current required for the device to go from operating state to
protected state
I
mA
trigger
V
V
V
V
= 650 V I
= 650 V I
= 650 V I
= 650 V I
(min.) = 100 mA TBU-DT065-100-WH
(min.) = 200 mA TBU-DT065-200-WH
(min.) = 300 mA TBU-DT065-300-WH
(min.) = 500 mA TBU-DT065-500-WH
imp
imp
imp
imp
trigger
trigger
trigger
trigger
5.6
4.8
Series resistance of
the TBU® device
Ω
R
R
device
V
V
V
V
= 850 V I
= 850 V I
= 850 V I
= 850 V I
(min.) = 100 mA TBU-DT085-100-WH
(min.) = 200 mA TBU-DT085-200-WH
(min.) = 300 mA TBU-DT085-300-WH
(min.) = 500 mA TBU-DT085-500-WH
10.3
7.4
6.5
5.8
12.1
8.7
7.7
6.9
+0.5
1
imp
imp
imp
imp
trigger
trigger
trigger
trigger
Package resistance matching of the TBU® device #1 - TBU® device #2
Time for the device to go from normal operating state to protected state
Current through the triggered TBU® device with 50 Vdc circuit voltage
Voltage below which the triggered TBU® device will transition to normal operating state
Junction to package pads - FR4 using recommended pad layout
-0.5
Ω
µs
mA
V
°C/W
°C/W
match
block
t
I
0.25
12
0.50
16
116
96
1.00
20
Q
V
reset
R
R
th(j-l)
th(j-l)
2
Junction to package pads - FR4 using heat sink on board (6 cm )
*RoHS Directive 2002/95/EC Jan 27, 2003 including Annex.
Specifications are subject to change without notice.