Series
MG800RW
Compact, 8W
2:1 Input, MiniDIP
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Key Features:
Conditions
12 VDC Input
Min.
9.0
Typ.
12.0
24.0
48.0
Max.
18.0
36.0
75.0
9.0
Units
VDC
• 8W Output Power
• Very Small MiniDIP Case
• EN 60950 Approved
• Wide 2:1 Input Range
• High Efficiency
Input Voltage Range
24 VDC Input 18.0
48 VDC Input 36.0
12 VDC Input
24 VDC Input
48 VDC Input
12 VDC Input
24 VDC Input
48 VDC Input
ꢀ (Pi) Filter
Input Start-up Threshold
Under Voltage Shutdown
18.0
36.0
VDC
VDC
8.0
16.0
34.0
• 1,500 VDC Isolation
• Single and Dual Outputs
• >1.0 MHour MTBF
• -40°C to +80°C Operation
• LOW COST
Input Filter
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Conditions
Min.
Typ.
Max.
2.0
2.0
0.8
1.0
55
Units
%
%
%
%
mV P - P
µSec
%
%
%/°C
Dual Output, Balanced Loads
VIN = Min To Max
1.0
0.2
0.5
Load Regulation
IOUT = 0% To 100%
See Note 2
Ripple & Noise (20 MHz)
Transient Recovery Time
Transient Response Deviation
Overload Protection
Temperature Coefficient
Output Short Circuit
General
500
5.0
See Note 3
See Note 4
3.0
150
0.01
0.02
See Note 5
Continuous (Autorecovery)
Parameter
Conditions
Min.
Typ.
Max.
Units
60 Seconds 1,500
1 Second 1,800
500 VDC 1,000
100 kHz, 1V
Isolation Voltage
VDC
Isolation Resistance
Isolation Capacitance
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Max Case Temperature
Storage Temperature Range
Cooling
M
pF
kHz
500
370
Conditions
Min.
Typ.
+25
Max.
+80
+105
+125
Units
°C
°C
Ambient
-40
-50
°C
Free Air Convection
RH, Non-condensing
Humidity
95
%
Physical
Case Size
Case Material
Weight
See Mechanical Diagram (Page 3)
Aluminum Alloy, Black Anodized Coating (UL-94V0)
0.20 Oz (6.1g)
MicroPower Direct
292 Page Street
Suite D
Reliability Specifications
Parameter
Stoughton, MA 02072
USA
Conditions
Min.
Typ.
Max.
Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign 1.06
UL 60950, EN 60950
MHours
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Safety Standards
Absolute Maximum Ratings
Parameter
Conditions
12 VDC Input
Min.
Typ.
Max.
25.0
50.0
100.0
260
Units
VDC
°C
Input Voltage Surge (1 Sec)
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
Lead Temperature
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com