APPLICABLE STANDARD
1
OPERATING
STORAGE
TEMPERATURE RANGE
-10 C TO +60 C (NOTE2)
-40 C TO +105 C (NOTE1)
TEMPERATURE RANGE
Storage Humidity Range
Operating Humidity Range
RATING
VOLTAGE
CURRENT
250 V AC
Relative humidity 85% max
(Not dewed)
3
A
SPECIFICATIONS
1
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
MARKING
ACCORDING TO DRAWING.
VISUALLY AND BY MEASURING INSTRUMENT.
CONFIRMED VISUALLY.
×
×
×
×
ELECTRIC CHARACTERISTICS
CONTACT RESISTANCE
CONTACT RESISTANCE
MILLIVOLT LEVEL METHOD
INSULATION RESISTANCE
1A DC.
30 mΩ MAX .
30 mΩ MAX .
100 MΩ MIN.
×
×
-
-
20 mV AC MAX, 0.1 mA(DC OR 1000Hz)
500 V DC.
×
×
-
-
VOLTAGE PROOF
1000 V AC FOR 1 min. 1
NO BREAKDOWN.
MECHANICAL CHARACTERISTICS
×
-
TERMINAL INSERTION AND
EXTRACTION FORCE
MEASURING AT 100mm/min.
4.9N MAX.
1
MECHANICAL OPERATION
30 TIMES INSERTIONS AND EXTRACTIONS.
① CONTACT RESISTANCE: 60 m MAX.
② NO DAMAGE, CRACK AND LOOSENESS
OF PARTS.
×
×
-
-
① NO ELECTRICAL DISCONTINUITY OF 10 s.
VIBRATION
SHOCK
FREQUENCY 20 TO 400 Hz,
×
×
×
-
-
-
43.1 m/s2 AT 3 h FOR
3
DIRECTIONS.
1
② CONTACT RESISTANCE: 60 m MAX.
③ NO DAMAGE, CRACK AND LOOSENESS OF
PARTS.
① NO ELECTRICAL DISCONTINUITY OF 10 s.
② CONTACT RESISTANCE: 60 m MAX.
③ NO DAMAGE, CRACK AND LOOSENESS OF
PARTS.
FREQUENCY 20 TO 50 Hz,
66.6 m/s2 AT 1 h .
×
×
×
-
-
-
LOCK STRENGTH
APPLYING A PULL FORCE THE MATING
AXIALLY AT 98N MAX.
① DURING APPLYING,MATING OMPLETELY.
② AFTER APPLYING,NO DEFECT OF MATING
PARTS.
×
×
-
-
ENVIRONMENTAL CHARACTERISTICS
DAMP HEAT
(STEADY STATE)
① CONTACT RESISTANCE: 60 m MAX.
② INSULATION RESISTANCE:100 M MIN.
③ NO DAMAGE, CRACK AND LOOSENESS
OF PARTS.
EXPOSED AT 60 C, 90 ~ 95 %, 500 h.
×
×
×
-
-
-
RAPID CHANGE OF
TEMPERATURE
① CONTACT RESISTANCE: 60 m MAX.
② INSULATION RESISTANCE:100 M MIN.
③ NO DAMAGE, CRACK AND LOOSENESS
OF PARTS.
TEMPERATURE- 40 →5 TO 35 →120 →5 TO 35C
TIME 30 → → 30 → 5 min
UNDER 1000 CYCLES.
×
×
×
-
-
-
5
1
DRY HEAT
EXPOSED AT 105C, 300 h.
① CONTACT RESISTANCE: 60 m MAX.
② NO DAMAGE, CRACK AND LOOSENESS
×
×
-
-
1
1
OF PARTS.
① CONTACT RESISTANCE: 60 m MAX.
② NO DAMAGE, CRACK AND LOOSENESS
OF PARTS.
×
×
-
-
COLD
EXPOSED AT -40C , 120 h.
RESISTANCE TO SO2 GAS
EXPOSED IN 500 PPM FOR 8h.
① CONTACT RESISTANCE: 60 m MAX.
② NO HEAVY CORROSION.
×
×
×
-
-
-
1
RESISTANCE TO
SOLDERING HEAT
SOLDERABILITY
NO DEFORMATION OF CASE OF EXCESSIVE
LOOSENESS OF THE TERMINALS.
SPECIFIED TEMPERATURE PROFILE FOR
2CYCLES.
SOLDERED AT SPECIFIED TEMPERATURE
PROFILE.
A NEW UNIFORM COATING OF SOLDER
SHALL COVER A MINIMUM OF 95 % OF
THE SURFACE BEING IMMERSED.
×
-
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
1
10
DIS-T-00010857
TY.IKEDA
HH.TSUKUMO
20210901
20200928
20200927
20200924
20200917
△
(NOTE1)
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
HK.UMEHARA
INCLUDE THE TEMPERATURE RISING BY CURRENT.
“STORAGE” MEANS A LONG-TERM STORAGE STATE FOR THE UNUSED PRODUCT BEFORE
HH.TSUKUMO
DONGCHAN KIM
GANG.LI
(NOTE2)
ASSEMBLY TO PCB.
1
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
PART NO.
CODE NO.
ELC-169257-60-00
GT25H-12DP-2.2V(60)
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
1
△
1/1
CL0775-0050-9-60
FORM HD0011-2-1