15~18W AC-DC Single Output Desktop
GS18A series
Features :
Universal AC input / Full range
No load power consumption<0.3W
ErP step2 compliant
Meet EISA 2007 (Energy Independence and Security Act)
3 pole AC inlet IEC320-C14
Class power (with earth pin)
Protections: Short circuit / Overload / Over voltage
Fully enclosed plastic case
LED indicator for power on
Approvals: UL / CUL / TUV / BSMI / CCC / PSE / CB / FCC / CE
Pass LPS
2 years warranty
(for 5V~28V only)
SPECIFICATION
ORDER NO.
GS18A05-P1J GS18A07-P1J GS18A09-P1J GS18A12-P1J GS18A15-P1J GS18A18-P1J GS18A24-P1J GS18A28-P1J GS18A48-P1J
SAFETY MODEL NO.
GS18A05
Note.2 5V
GS18A07
7.5V
GS18A09
9V
GS18A12
12V
GS18A15
15V
GS18A18
18V
GS18A24
24V
GS18A28
28V
GS18A48
48V
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
3.0A
2.0A
2.0A
1.50A
0 ~ 1.50A
18W
1.20A
1.0A
0.75A
0.64A
0.375A
0 ~ 0.375A
18W
0 ~ 3.0A
15W
0 ~ 2.0A
15W
0 ~2.0A
18W
0 ~ 1.20A
18W
0 ~ 1.0A
18W
0 ~ 0.75A
18W
0 ~ 0.64A
18W
OUTPUT
RIPPLE & NOISE (max.) Note.3 50mVp-p
VOLTAGE TOLERANCE Note.4 5.0%
80mVp-p
5.0%
80mVp-p
5.0%
80mVp-p
3.0%
100mVp-p
3.0%
150mVp-p
3.0%
180mVp-p
2.0%
240mVp-p
2.0%
240mVp-p
2.0%
LINE REGULATION
LOAD REGULATION
Note.5 1.0%
Note.6 5.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
5.0%
5.0%
3.0%
3.0%
3.0%
2.0%
2.0%
2.0%
SETUP, RISE, HOLD UP TIME 500ms, 20ms, 50ms/230VAC
500ms, 20ms, 15ms/115VAC at full load
VOLTAGE RANGE
90 ~ 264VAC 135 ~ 370VDC
47 ~ 63Hz
FREQUENCY RANGE
EFFICIENCY (Typ.)
79.5%
82%
83%
85%
85%
85%
86%
86.5%
87%
INPUT
AC CURRENT
0.5A / 100VAC
45A / 230VAC
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
0.75mA / 240VAC
110 ~ 150% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
PROTECTION
OVER VOLTAGE
Protection type : Clamp by zener diode, output short
0 ~ +50 (Refer to "Derating Curve")
WORKING TEMP.
20% ~ 90% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-20 ~ +85 , 10 ~ 95% RH
ENVIRONMENT
0.03% / (0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336, PSE J60950-1(5~28V only), CCC GB4943 approved
I/P-O/P:4242VDC , I/P-FG:2121VDC
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY &
I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25 / 70% RH
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
EMC
(Note. 7)
Compliance to EN55022, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB9254
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
500Khrs min. MIL-HDBK-217F(25
93*54*36mm (L*W*H)
)
DIMENSION
OTHERS
230g ; 60pcs / 15kg / CARTON
See page2
PACKING
PLUG
CONNECTOR
CABLE
See page2
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
NOTE
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 20% to 100% rated load
7.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives.
File Name:GS18A-SPEC 2011-06-14