15~18W AC-DC Single Output Desktop
GS18B series
Features :
Universal AC input / Full range
No load power consumption<0.3W
ErP step2 compliant
Meet EISA 2007 (Energy Independence and Security Act)
2 pole AC inlet IEC320-C8
Class power (without earth pin)
Protections: Short circuit / Overload / Over voltage
Fully enclosed plastic case
LED indicator for power on
Approvals: UL / CUL / TUV / BSMI / CCC / CB / FCC / CE
Pass LPS
2 years warranty
SPECIFICATION
ORDER NO.
GS18B05-P1J GS18B07-P1J GS18B09-P1J GS18B12-P1J GS18B15-P1J GS18B18-P1J GS18B24-P1J GS18B28-P1J GS18B48-P1J
SAFETY MODEL NO.
GS18B05
Note.2 5V
GS18B07
7.5V
GS18B09
9V
GS18B12
12V
GS18B15
15V
GS18B18
18V
GS18B24
24V
GS18B28
28V
GS18B48
48V
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
3.0A
2.0A
2.0A
1.50A
0 ~ 1.50A
18W
1.20A
1.0A
0.75A
0.64A
0.375A
0 ~ 0.375A
18W
0 ~ 3.0A
15W
0 ~ 2.0A
15W
0 ~2.0A
18W
0 ~ 1.20A
18W
0 ~ 1.0A
18W
0 ~ 0.75A
18W
0 ~ 0.64A
18W
OUTPUT
RIPPLE & NOISE (max.) Note.3 50mVp-p
VOLTAGE TOLERANCE Note.4 5.0%
80mVp-p
5.0%
80mVp-p
5.0%
80mVp-p
3.0%
100mVp-p
3.0%
150mVp-p
3.0%
180mVp-p
2.0%
240mVp-p
2.0%
240mVp-p
2.0%
LINE REGULATION
LOAD REGULATION
Note.5 1.0%
Note.6 5.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
5.0%
5.0%
3.0%
3.0%
3.0%
2.0%
2.0%
2.0%
SETUP, RISE, HOLD UP TIME 500ms, 20ms, 50ms/230VAC
500ms, 20ms, 15ms/115VAC at full load
VOLTAGE RANGE
90 ~ 264VAC 135 ~ 370VDC
47 ~ 63Hz
FREQUENCY RANGE
EFFICIENCY (Typ.)
79.5%
82%
83%
85%
85%
85%
86%
86.5%
87%
INPUT
AC CURRENT
0.5A / 100VAC
45A / 230VAC
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
0.25mA / 240VAC
110 ~ 150% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
PROTECTION
OVER VOLTAGE
Protection type : Clamp by zener diode, output short
0 ~ +50 (Refer to "Derating Curve")
WORKING TEMP.
20% ~ 90% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-20 ~ +85 , 10 ~ 95% RH
ENVIRONMENT
0.03% / (0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336, CCC GB4943 approved
I/P-O/P:4242VDC
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY &
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
EMC
(Note. 7)
Compliance to EN55022, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB9254
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
500Khrs min. MIL-HDBK-217F(25
79*54*33mm (L*W*H)
)
DIMENSION
OTHERS
210g ; 60pcs / 13.5kg / CARTON
See page2
PACKING
PLUG
CONNECTOR
CABLE
See page2
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
NOTE
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 20% to 100% rated load
7.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives.
File Name:GS18B-SPEC 2011-06-14