10~18W AC-DC Single Output Desktop
GS18A series
Features :
Universal AC input / Full range
No load power consumption<0.5W
Pass energy star(CEC) level
for 5~48V output
Meet EISA 2007 (Energy Independence and Security Act) for 5 ~ 48V
3 pole AC inlet IEC320-C14
Class power (with earth pin)
Full output 3~48V safety approval
Protections: Short circuit / Overload / Over voltage
Fully enclosed plastic case
LED indicator for power on
Approvals: UL / CUL / TUV / BSMI / CB / FCC / CE
Pass LPS for 9~48V output
2 years warranty
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
SPECIFICATION
ORDER NO.
GS18A03-P1J GS18A05-P1J GS18A07-P1J GS18A09-P1J GS18A12-P1J GS18A15-P1J GS18A18-P1J GS18A24-P1J GS18A28-P1J GS18A48-P1J
GS18A03 GS18A05 GS18A07 GS18A09 GS18A12 GS18A15 GS18A18 GS18A24 GS18A28 GS18A48
Note.2 3.3V
SAFETY MODEL NO.
DC VOLTAGE
5V
7.5V
9V
12V
15V
18V
24V
28V
48V
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
3.0A
3.0A
2.0A
2.0A
1.50A
1.20A
1.0A
0.75A
0.64A
0.375A
0 ~ 3.0A
10W
0 ~ 3.0A
15W
0 ~ 2.0A
15W
0 ~2.0A
18W
0 ~ 1.50A 0 ~ 1.20A 0 ~ 1.0A
0 ~ 0.75A 0 ~ 0.64A 0 ~ 0.375A
18W 18W 18W
100mVp-p 150mVp-p 180mVp-p 240mVp-p 240mVp-p
18W
18W
18W
OUTPUT
RIPPLE & NOISE (max.) Note.3 50mVp-p
VOLTAGE TOLERANCE Note.4 5.0%
50mVp-p
5.0%
1.0%
5.0%
80mVp-p
5.0%
80mVp-p
5.0%
1.0%
5.0%
80mVp-p
3.0%
3.0%
1.0%
3.0%
3.0%
1.0%
3.0%
2.0%
1.0%
2.0%
2.0%
1.0%
2.0%
2.0%
1.0%
2.0%
LINE REGULATION
LOAD REGULATION
Note.5 1.0%
Note.6 5.0%
1.0%
1.0%
5.0%
3.0%
SETUP, RISE, HOLD UP TIME 500ms, 20ms, 50ms/230VAC
500ms, 20ms, 15ms/115VAC at full load
VOLTAGE RANGE
90 ~ 264VAC 135 ~ 370VDC
47 ~ 63Hz
FREQUENCY RANGE
EFFICIENCY (Typ.)
68%
73%
79%
79%
81%
81%
82%
84%
84%
85%
INPUT
AC CURRENT
0.5A / 100VAC
45A / 230VAC
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
0.75mA / 240VAC
110 ~ 150% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
PROTECTION
ENVIRONMENT
OVER VOLTAGE
Protection type : Clamp by zener diode, output short
0 ~ +50 (Refer to output load derating curve)
20% ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-20 ~ +85 , 10 ~ 95% RH
0.03% / (0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336
I/P-O/P:4242VDC , I/P-FG:2121VDC
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY &
I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 class B, FCC PART 15 / CISPR22 class B, CNS13438 class B
Compliance to EN61000-3-2,3
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMC
(Note. 7)
EMS IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
500Khrs min. MIL-HDBK-217F(25
93*54*36mm (L*W*H)
)
DIMENSION
OTHERS
230g ; 60pcs / 15kg / CARTON
PACKING
PLUG
Standard type P1J: 2.1 * 5.5 * 11mm, tuning fork type, center positive for stock ; Other type available by customer requested
Standard type UL1185 6ft (4FT for 3.3 ~ 5V output) for stock ; Other type available by customer requested
CONNECTOR
CABLE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
NOTE
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 20% to 100% rated load
7.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:GS18A-SPEC 2008-05-08