5kW-Fast - Series Specifications
Unless otherwise noted, specifications are warranted over the ambient temperature 10°C - 50°C.
20-250-F
30-170-F
40-125-F
OUTPUT RATING
1.Rated output voltage (*1)
2.Rated output current (*2)
3.Rated output power
V
A
20
30
40
250
170
125
W
5000
5100
5000
V
20
30
40
INPUT CHARACTERISTICS
1.Input voltage/freq. 3 phase, 3 wire+ground (*3)
3-Phase, 200V models: 170~265Vac, 47~63Hz (Covers 200/230Vac).
3-Phase, 400V models: 342~460Vac, 47~63Hz (Covers 380/400/415Vac).
---
---
3-Phase, 480V models: 342~528Vac, 47~63Hz (Covers 380/400/415/440/460/480Vac).
2.Maximum Input
current at 100% load
3-Phase, 200V models:
3-Phase, 400V models:
3-Phase, 480V models:
17.5A @ 200Vac.
9.2A @ 380Vac.
9.2A @ 380Vac.
3.Power Factor (Typ.)
---
%
0.94 @ 200/380Vac, rated output power.
4.Efficiency (Typ.) (*4) (*18)
5.Inrush current (*5)
91
91
91
40
---
Less than 50A.
CONSTANT VOLTAGE MODE
V
20
30
1.Max. Line regulation (*6)
---
---
0.01% of rated output voltage.
2.Max. Load regulation (*7)
3.Ripple & noise (p-p, 20MHz) (*8) (*19)
4.Ripple r.m.s. 5Hz~1MHz (*8) (*19)
5.Temperature coefficient
0.01% of rated output voltage +5mV.
mV
mV
---
150
300
55
200
35
20
50PPM/OC from rated output voltage, following 30 minutes warm-up.
6.Temperature stability
---
0.01% of rated Vout over 8hrs. interval following 30 minutes warm-up. Constant line, load & temperature.
Less than 0.05% of rated output voltage +2mV over 30 minutes following power on.
7.Warm-up drift
---
8.Remote sense compensation/wire (*9)
9.Up-prog. response time (*10)
V
2
5
5
mS
<
1
<
1
<1
10.Down-prog.
response time
Full load (*10)
No load (*11)
<1
<1.5
<80
<2
mS
<60
<100
11.Transient response time
Time for output voltage to recover within 0.5% of its rated output for a load change 10~90% of rated output current.
Output set point: 10~100%, Local sense.
Less than 1mS for models up to and including 100V. 2mS for models above 100V.
---
12.Start-up delay
13.Hold-up time
---
---
Less than 5Sec.
5mS Typical. Rated output power.
V
20
30
40
CONSTANT CURRENT MODE
1.Max. Line regulation (*6)
2.Max. Load regulation (*12)
3.Ripple r.m.s. 5Hz~1MHz (*13) (*19)
4.Temperature coefficient
5.Temperature stability
---
---
0.05% of rated output current.
0.08% of rated output current.
mA
---
<
850
<
350
<250
100PPM/OC from rated output current, following 30 minutes warm-up.
---
0.01% of rated Iout over 8hrs. interval following 30 minutes warm-up. Constant line, load & temperature.
Less than +/-0.25% of rated output current over 30 minutes following power on.
6.Warm-up drift
---
ANALOG PROGRAMMING AND MONITORING (ISOLATED FROM THE OUTPUT)
1.Vout voltage programming
2.Iout voltage programming (*14)
3.Vout resistor programming
4.Iout resistor programming (*14)
5.Output voltage monitor
---
---
---
---
---
---
0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity: +/-0.15% of rated Vout.
0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity: +/-0.4% of rated Iout.
0~100%, 0~5/10KΩ full scale, user selectable. Accuracy and linearity: +/-0.5% of rated Vout.
0~100%, 0~5/10KΩ full scale, user selectable. Accuracy and linearity: +/-0.5% of rated Iout.
0~5V or 0~10V, user selectable. Accuracy: +/-0.5% of rated Vout.
6.Output current monitor (*14)
0~5V or 0~10V, user selectable. Accuracy: +/-0.5% of rated Iout.
10