NOTES:
*1: Minimum voltage is guaranteed to maximum 0.1% of rated output voltage.
*2: Minimum current is guaranteed to maximum 0.2% of rated output current.
*3: For cases where conformance to various safety standards (UL, IEC, etc…) is required, to be described as 190-240Vac (50/60Hz) for 3-Phase 200V models
380~415Vac (50/60Hz) for 3-Phase 400V models and 380~480Vac (50/60Hz) for 3-Phase 480V models.
*4: 3-Phase 200V models: At 200Vac input voltage, 3-Phase 400/480V: At 380Vac input voltage. With rated output power.
*5: Not including EMI filter inrush current, less than 0.2mS.
*6: 3-Phase 200V models: 170~265Vac, 3-Phase 400V models: 342~460Vac, 3-Phase 480V models: 342~528Vac. Constant load.
*7: From No-Load to Full-Load, constant input voltage. Measured at the sensing point in Remote Sense.
*8: Measured with JEITA RC-9131C (1:1) probe.
*9: The maximum voltage on the power supply terminals must not exceed the rated voltage.
*10: From 10% to 90% of Rated Output Voltage at rated resistive load.
*11: From 90% to 10% of Rated Output Voltage.
*12: For load voltage change, equal to the unit voltage rating, constant input voltage.
*13: The Ripple is measured at 10~100% of rated output voltage and rated output current. B.W 5Hz~1MHz.
*14: The Constant Current programming, readback and monitoring accuracy do not include the warm-up and Load regulation thermal drift.
*15: Measured at the sensing point.
*16: Signal and control ports interface cables length: Less than 3m, DC output power port cables length: Less than 30m.
*17: Max. ambient temperature for IEEE is 40°C.
*18: Typ. at Ta=25°C, rated output power.
*19: At Tamb < 10°C the Output Ripple & Noise is higher, there is a need of 2min warm-up.
To achieve high-speed respond, the output capacitance has been reduced.
Due to smaller capacitance, the output ripple & noise is higher, but it's not a problem for applications requiring high speed power supply as Automotive industry
13