3.4kW-Fast Series Specifications
Unless otherwise noted, specifications are warranted over the ambient temperature of 10°C - 50°C.
OUTPUT RATING
20-170-F
20
30-112-F
30
40-85-F
40
1.Rated output voltage (*1)
2.Rated output current (*2)
3.Rated output power
V
A
170
112
85
W
3400
3360
3400
INPUT CHARACTERISTICS
V
20
30
40
1.Input voltage/freq. 3-Phase, 3 wire+ground (*4)
1-Phase, 2 wire+ground
3-Phase, 200V models: 170~265Vac, 47~63Hz (Covers 200/230Vac).
3-Phase, 400V models: 342~460Vac, 47~63Hz (Covers 380/400/415Vac).
---
3-Phase, 480V models: 342~528Vac, 47~63Hz (Covers 380/400/415/440/460/480Vac).
1-Phase models: 170~265Vac, 47~63Hz (Covers 200/208/230/240).
12.5A @ 200Vac.
2.Maximum input current at 3-Phase, 200V models
100% load (*19)
3-Phase, 400V models
3-Phase, 480V models
1-Phase models
6.5A @ 380Vac.
---
---
6.5A @ 380Vac.
21A @ 200Vac.
3.Power Factor (Typ.)
For 3-Phase: 0.94 @ 200/380Vac, rated output power.
For 1-Phase: 0.99 @ 200Vac, rated output power.
4.Efficiency (Typ.) (*5) (*20)
5.Inrush current (*6)
%
89
89.5
90
40
---
Less than 50A.
CONSTANT VOLTAGE MODE
V
---
20
30
1. Max. Line regulation (*7)
0.01% of rated output voltage.
2. Max. Load regulation (*8)
---
0.01% of rated output voltage +5mV.
3. Ripple & Noise 3-Phase (p-p, 20MHz) (*9) (*20)
4. Ripple r.m.s. 5Hz~1MHz for 3-Phase (*9) (*20)
5. Ripple & Noise 1-Phase (p-p, 20MHz) (*9) (*20)
6. Ripple r.m.s. 5Hz~1MHz for 1-Phase (*9) (*20)
7.Temperature coefficient
mV
mV
mV
mV
---
120
15
300
35
150
20
130
20
350
40
200
25
50PPM/OC from rated output voltage, following 30 minutes warm-up.
8.Temperature stability
---
0.01% of rated Vout over 8hrs interval following 30 minutes warm-up. Constant line, load & temperature.
Less than 0.05% of rated output voltage +2mV over 30 minutes following power on.
9.Warm-up drift
---
10.Remote sense compensation/wire (*10)
11.Up-prog. response time (*11)
V
2
5
5
mS
<1
<1
<1
12.Down-prog. response time
Full load (*11)
No load (*12)
<1.3
<80
<1.3
<120
<1.3
<120
mS
---
13.Transient response time
Time for output voltage to recover within 0.5% of its rated output for a load change 10~90% of rated
output current. Output set point: 10~100%, Local sense.
Less than 1mS for models up to and including 100V.
14.Start-up delay
15.Hold-up time
---
---
Less than 6Sec.
For 3-Phase: 7mS Typical, rated output power. For 1-Phase: 10mS Typical, rated output power.
V
20
30
40
CONSTANT CURRENT MODE
1.Max. Line regulation (*7)
2.Max. Load regulation (*13)
---
---
0.05% of rated output current.
0.08% of rated output current.
3.Ripple r.m.s. 5Hz~1MHz for 3-Phase (*14) (*20)
4.1. Ripple r.m.s. 5Hz~1MHz for 1-Phase (*14) (*20)
5.Temperature coefficient
mA
mA
---
<600
<800
<400
<400
<200
<400
10V~100V models: 100PPM/OC from rated output current, following 30 minutes warm-up.
0.01% of rated Iout over 8hrs. interval following 30 minutes warm-up. Constant line, load & temperature.
10V~100V models: Less than +/-0.25% of rated output current over 30 minutes following power on.
6.Temperature stability
---
7.Warm-up drift
---
ANALOG PROGRAMMING AND MONITORING (ISOLATED FROM THE OUTPUT)
1.Vout voltage programming
2.Iout voltage programming (*15)
3.Vout resistor programming
4.Iout resistor programming (*15)
5.Output voltage monitor
---
---
---
---
---
---
0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity: +/-0.15% of rated Vout.
0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity: +/-0.4% of rated Iout.
0~100%, 0~5/10KΩ full scale, user selectable. Accuracy and linearity: +/-0.5% of rated Vout.
0~100%, 0~5/10KΩ full scale, user selectable. Accuracy and linearity: +/-0.5% of rated Iout.
0~5V or 0~10V, user selectable. Accuracy: +/-0.5% of rated Vout.
6.Output current monitor (*15)
0~5V or 0~10V, user selectable. Accuracy: +/-0.5% of rated Iout.
SIGNALS AND CONTROLS (ISOLATED FROM THE OUTPUT)
1.Power supply OK #1 signal
---
---
---
---
---
---
---
Power supply output monitor. Open collector. Output On: On. Output Off: Off.
Maximum Voltage: 30V. Maximum Sink Current: 10mA.
2.CV/CC signal
CV/CC Monitor. Open collector. CC mode: On. CV mode: Off. Maximum Voltage: 30V.
Maximum Sink Current: 10mA.
3.LOCAL/REMOTE Analog control
4.LOCAL/REMOTE Analog signal
5.ENABLE/DISABLE signal
6.INTERLOCK (ILC) control
7.Programmed signals
Enable/Disable analog programming control by electrical signal or dry contact. Remote: 0~0.6V or short.
Local: 2~30V or open.
Analog programming control monitor signal. Open collector. Remote: On. Local: Off.
Maximum Voltage: 30V. Maximum Sink Current: 10mA.
Enable/Disable PS output by electrical signal or dry contact.
0~0.6V or short, 2~30V or open. User selectable logic.
Enable/Disable PS output by electrical signal or dry contact.
Output ON: 0~0.6V or short. Output OFF: 2~30V or open.
Two open drain programmable signals. Maximum voltage 25V. Maximum sink current 100mA
(shunted by 27V zener).
8.TRIGGER IN / TRIGGER OUT signals
Maximum low level input voltage = 0.8V. Minimum high level input voltage = 2.5V.
Maximum high level input = 5V positive edge trigger: tw = 10us minimum. Tr,Tf = 1us maximum.
Min delay between 2 pulses 1ms.
---
9.DAISY_IN/SO control signal
---
---
By electrical Voltage: 0~0.6V/2~30V or dry contact.
10.DAISY_OUT/PS_OK #2 signal
4~5V = OK, 0V (500Ω impedance) = Fail.
7