ELANC Series
Single Output
“Economy” Version of LANC Series
FEATURES
● High Efficiency up to 83%
● 500VDC Isolation Voltage
● Low Output Ripple & Noise
● Economy Version of LANC Series
● Single Output: 3.3V, 5V, 12V, 15V
● Ultra Wide Input Voltage Range: 18-75VDC
● Meets IEC/EN60950, UL60950 Safety Standards
● Industry Standard Footprint: 1.25 x 0.8 x 0.4 Inches
SPECIFICATIONS: ELANC Series
All specifications apply @ ±25°C ambient unless otherwise noted
INPUT SPECIFICATIONS
GENERAL SPECIFICATIONS
Input Voltage Range ...................................................18 - 75VDC
Efficiency ..........................................................................see table
Nominal Input Voltage........................................................48VDC
Isolation Voltage
Input to Output................................................500VDC for 1 min.
Input to Case..................................................500VDC for 1 min.
Output to Case ...............................................500VDC for 1 min.
OUTPUT SPECIFICATIONS
Output Current ................................................................see table
Output Voltage ................................................................see table
Voltage Adjustability...............................................................none
Voltage Setpoint Accuracy.................................... ±3.0% Vo max.
Line Regulation ....................................................... 0.5% Vo max.
Load Regulation...................................................... 1.0% Vo max.
Maximum Power ...................................................................... 6W
Ripple & Noise .................................................... < 60mVp-p max.
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature ..........................-40°C to +85°C (ambient)
Storage Temperature............................................ -55°C to +125°C
Operating Board Temperature.............................. -40°C to +100°C
Temperature Coefficient .............................................. <±0.02%/°C
MTBF.................................................................. >2,000,000 hours
PHYSICAL SPECIFICATIONS
Transient Response.................................................. 200mV max.
Recovery < 200µs max.
Dimensions.................................. 1.25(L) x 0.8(W) x 0.4(H) inches
31.8(L) x 20.3(W) x 10.16(H) mm
(25% load step change from 50% Io)
di/dt: 1A/10µs
SAFETY
Safety Standards ......................................IEC/EN60950, UL60950
Due to advances in technology, specifications subject to change without notice
OUTPUT VOLTAGE / CURRENT RATING CHART
Model
Input Voltage
Output Voltage Output Current Output Power
Efficiency
ELANC4833UW5
ELANC4805UW6
ELANC4812UW6
ELANC4815UW6
3.3 VDC
5 VDC
1.5A
1.2A
0.5A
0.4A
5W
6W
6W
6W
76%
80%
82%
83%
48 VDC
(18 – 75 VDC)
12 VDC
15 VDC
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833