DS1217M Nonvolatile Read/Write Cartridge
ABSOLUTE MAXIMUM RATINGS
Voltage Range on Connection Relative to Ground
Operating Temperature Range
-0.3V to + 7.0V
0°C to +70°C
Storage Temperature Range
-40°C to +70°C
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only,
and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is
not implied. Exposure to the absolute maximum rating conditions for extended periods may affect device reliability.
RECOMMENDED DC OPERATING CONDITIONS
(TA = 0°C to +70°C)
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
UNITS
Power Supply Voltage
Input High Voltage
Input Low Voltage
VCC
VIH
VIL
4.5
2.2
0
5.0
5.5
VCC
+0.8
V
V
V
DC ELECTRICAL CHARACTERISTICS
(VCC = 5V ±10%, TA = 0°C to +70°C.)
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
UNITS
Input Leakage Current
IIL
-60
+60
A
I/O Leakage Current
CE VIH VCC
IIO
IOH
-10
-1.0
+2.0
+10
A
mA
mA
mA
mA
Output Current at 2.4V
Output Current at 0.4V
Standby Current CE = 2.2V
Operating Current
-2.0
+3.0
15
IOL
ICCS1
ICCO1
25
50
100
CAPACITANCE
(TA = +25°C)
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
UNITS
Input Capacitance
CIN
100
100
pF
pF
Input/Output Capacitance
COUT
2 of 8