A 108, A 101, A 208, A 201
Output Specifications
A 108, A 101
A 208, A 201
Output
Basic electrical insulation
SPDT relay
250 VAC (rms) (contact/electronics)
DPDT relay
250 VAC (rms) (contacts/elec., contact/contact)
Contact ratings (Ag-CdO)
µ (micro gap)
µ (micro gap)
Resistive loads
AC 1 10 A/250 VAC (2500 VA)
DC 1 1 A/250 VDC (250 W)
or 10 A/25 VDC (250 W)
8 A/250 VAC (2000 VA)
0.4 A/250 VDC (100 W)
4 A/25 VDC (100 W)
2.5 A/230 VAC
Small inductive loads AC 15 2.5 A/230 VAC
DC 13 5 A/24 VDC
5 A/24 VDC
Mechanical life
Electrical life
≥ 30 x 106 operations
AC 1 ≥ 2.5 x 105 operations (at max. load)
≥ 30 x 106 operations
≥ 2.5 x 105 operations (at max. load)
Operating frequency
≤ 7200 operations/h
≤ 7200 operations/h
Insulation voltages
Rated insulation voltage
≥ 2.0 kVAC (rms) (contact/electronics)
≥ 2.0 kVAC (rms) (contact/electronics)
Rated transient protection volt. 4 kV (1.2/50 µs) (contact/electronics) (IEC 60664)
4 kV (1.2/50 µs) (contact/electronics) (IEC 60664)
Supply Specifications
General Specifications
Power-on delay
Power-off delay
Indication for
Output ON
≤ 200 ms
≥ 250 ms
Power supply AC types
installation cat. III (IEC 60664)
Rated operational voltage
through pins 2 & 10
or pins 2 & 7
220
220 VAC + 15/- 20%,
45 to 65 Hz
120 VAC + 15/- 20%,
45 to 65 Hz
24 VAC + 15/- 20%,
45 to 65 Hz
≥ 10 ms
LED, red
IP 20 B
2 (IEC 60664)
-20° to +50°C (-4° to +122°F)
-50° to +85°C (-58° to +185°F)
120
024
Environment
Polution degree
Operating temperature
Storage temperature
Drop out tolerance
Rated insulation voltage
Rated transient protection volt. 4 kV (1.2/50 µs) @ 220 VAC
2.5 kV (1.2/50 µs) @ 120 VAC
None
Weight
Approvals
85 g
UL, CSA
800 V (1.2/50 µs) @ 24 VAC
(line/neutral)
Power supply DC type
Rated operational voltage 024 24 VDC + 15/- 20% (pin 2 pos.)
Rated insulation voltage None
Rated transient protection volt. 800 V (1.2/50 µs)
Installation cat. III (IEC 60664)
Consumption
AC supply
DC supply
60 mA @ 50 Hz/70 mA @ 60 Hz
1 W
Wiring Diagrams
Mode of Operation
The delay period begins when If power supply is interrupted
power supply is applied.
for more than 250 ms before
the relay operates, the time
At the end of the set delay, circuit is reset to zero and the
the relay will operate and will time relay is ready for a new
not release until power sup- time period.
ply is interrupted.
A recovery period of 250 ms
should be allowed before re-
applying power supply.
Power supply
A 108, A 208
Power supply
A 101, A 201
2
Specifications are subject to change without notice (25.10.99)