74LVCV2G66
NXP Semiconductors
Overvoltage tolerant bilateral switch
8. Limiting values
Table 5:
Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134). Voltages are referenced to GND (ground = 0 V).
Symbol
VCC
VI
Parameter
Conditions
Min
−0.5
−0.5
−50
-
Max
+6.5
+6.5
-
Unit
V
supply voltage
[1]
input voltage
V
IIK
input clamping current
switch clamping current
switch voltage
VI < −0.5 V or VI > 6.5 V
VI < −0.5 V or VI > 6.5 V
enable and disable mode
VSW > −0.5 V or VSW < 6.5 V
mA
mA
V
ISK
±50
+6.5
±50
100
-
VSW
ISW
−0.5
-
switch current
mA
mA
mA
°C
ICC
supply current
-
IGND
Tstg
Ptot
ground current
−100
−65
-
storage temperature
total power dissipation
+150
250
[2]
Tamb = −40 °C to +125 °C
mW
[1] The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
[2] For TSSOP8 package: above 55 °C the value of Ptot derates linearly with 2.5 mW/K.
For VSSOP8 package: above 110 °C the value of Ptot derates linearly with 8 mW/K.
For XSON8U package: above 118 °C the value of Ptot derates linearly with 7.8 mW/K.
9. Recommended operating conditions
Table 6:
Symbol
VCC
Recommended operating conditions
Parameter
Conditions
Min
2.3
0
Typ
Max
5.5
5.5
5.5
+125
20
Unit
V
supply voltage
input voltage
-
-
-
-
-
-
VI
V
[1]
VSW
switch voltage
ambient temperature
enable and disable mode
0
V
Tamb
−40
-
°C
[2]
[2]
Δt/ΔV
input transition rise and fall rate VCC = 2.3 V to 2.7 V
VCC = 2.7 V to 5.5 V
ns/V
ns/V
-
10
[1] To avoid sinking GND current from terminal nZ when switch current flows in terminal nY, the voltage drop across the bidirectional switch
must not exceed 0.4 V. If the switch current flows into terminal nZ, no GND current will flow from terminal nY. In this case, there is no
limit for the voltage drop across the switch.
[2] Applies to control signal levels.
74LVCV2G66
All information provided in this document is subject to legal disclaimers.
© NXP B.V. 2010. All rights reserved.
Product data sheet
Rev. 3 — 16 June 2010
4 of 23