Nexperia
74AUP2G02
Low-power dual 2-input NOR gate
9. Recommended operating conditions
Table 6. Operating conditions
Symbol Parameter
Conditions
Min
0.8
0
Max
3.6
Unit
V
VCC
VI
supply voltage
input voltage
output voltage
3.6
V
VO
Active mode
0
VCC
3.6
V
Power-down mode; VCC = 0 V
0
V
Tamb
ambient temperature
-40
0
+125
200
°C
ns/V
Δt/ΔV
input transition rise and fall rate
VCC = 0.8 V to 3.6 V
10. Static characteristics
Table 7. Static characteristics
At recommended operating conditions; voltages are referenced to GND (ground = 0 V).
Symbol Parameter
Tamb = 25 °C
Conditions
Min
Typ
Max
Unit
VIH
HIGH-level input voltage VCC = 0.8 V
VCC = 0.9 V to 1.95 V
0.70 × VCC
-
-
-
-
-
-
-
-
-
V
V
V
V
V
V
V
V
0.65 × VCC
-
VCC = 2.3 V to 2.7 V
VCC = 3.0 V to 3.6 V
1.6
-
2.0
-
VIL
LOW-level input voltage VCC = 0.8 V
-
-
-
-
0.30 × VCC
0.35 × VCC
0.7
VCC = 0.9 V to 1.95 V
VCC = 2.3 V to 2.7 V
VCC = 3.0 V to 3.6 V
0.9
VOH
HIGH-level output
voltage
VI = VIH or VIL
IO = -20 μA; VCC = 0.8 V to 3.6 V
IO = -1.1 mA; VCC = 1.1 V
IO = -1.7 mA; VCC = 1.4 V
IO = -1.9 mA; VCC = 1.65 V
IO = -2.3 mA; VCC = 2.3 V
IO = -3.1 mA; VCC = 2.3 V
IO = -2.7 mA; VCC = 3.0 V
IO = -4.0 mA; VCC = 3.0 V
VI = VIH or VIL
VCC - 0.1
0.75 × VCC
1.11
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
V
V
V
V
V
V
V
V
1.32
2.05
1.9
2.72
2.6
VOL
LOW-level output
voltage
IO = 20 μA; VCC = 0.8 V to 3.6 V
IO = 1.1 mA; VCC = 1.1 V
IO = 1.7 mA; VCC = 1.4 V
IO = 1.9 mA; VCC = 1.65 V
IO = 2.3 mA; VCC = 2.3 V
IO = 3.1 mA; VCC = 2.3 V
IO = 2.7 mA; VCC = 3.0 V
IO = 4.0 mA; VCC = 3.0 V
VI = GND to 3.6 V; VCC = 0 V to 3.6 V
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0.1
0.3 × VCC
0.31
V
V
V
V
V
V
V
V
μA
0.31
0.31
0.44
0.31
0.44
II
input leakage current
±0.1
©
74AUP2G02
All information provided in this document is subject to legal disclaimers.
Nexperia B.V. 2021. All rights reserved
Product data sheet
Rev. 9 — 27 July 2021
4 / 17