BURNDY
Compression
BEVELED
ENTRY
ONE HOLE HYLUG™
DIE AND COLOR
CODE INFORMATION
CODE CONDUCTOR
LONG BARREL
NO INSPECTION
WINDOW
TYPES YA,YA-TC
CRIMPS
UNINSULATED COPPER
COMPRESSION TERMINAL
CABLE
ACCOMMODATION
ELECTRO-TIN
PLATED
C-16
UL Listed 90° C,
600 Volts to 35 KV ◆
B
90°
B
T
T
T
45°
L
L
L
Fig. 1
Fig. 3
Fig. 2
Conductor
***
◆ Installation Tooling
Stud
Hole Tongue
Figure
Dimensions
(T)
Mechanical
Hydraulic
Wire
Strip
Dieless
(# of crimps)
MD6, OUR840, BCT500HS,
MD7-34R Y500CTHS
Y35,Y39,Y750
Y46*, PAT750
Color Die
Catalog Number
YA8C-TC10
YA8C-TC10-45
YA8C-TC10-90
YA8C-TC14
YA8C-TC14-45
YA8C-TC14-90
YA8C-TC38
YA8C-TC38-45
YA8C-TC38-90
YA6C-TC10
YA6C-TC10-45
YA6C-TC10-90
YA6C-N
Fig #
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
AWG
MM2 Size
Width
(B)
(L)
Code Index Length
1.57ꢀ
1.46ꢀ
.68ꢀ
#8 AWG
#8 WELD
37/24
# 10 .38ꢀ
.81ꢀ
.08ꢀ
.08ꢀ
.06ꢀ
MRC840 (2)
Y8MBR-1 (1)
Y2MR (2)
1.69ꢀ
1.57ꢀ
.86ꢀ
W8CVT (2) X8CRT (2)
W8CRT (2) W8CVT (2)
X8CRT (2) W8CRT (2)
†
1/4ꢀ
3/8ꢀ
.41ꢀ
.58ꢀ
.81ꢀ
.81ꢀ
U8CRT (2)
Red 49
1ꢀ
10
Y1MR (2)
1.88ꢀ
1.71ꢀ
1.04ꢀ
1.89ꢀ
1.72ꢀ
.75ꢀ
#6 SOL
# 10 .41ꢀ
1.12ꢀ .09ꢀ
1.12ꢀ .12ꢀ
1.12ꢀ .09ꢀ
1.12ꢀ .07ꢀ
1.12ꢀ .12ꢀ
MRC840 (2)
MY29-3 (2) W5CVT (2) W5CVT (2)
MY29-11 (2) W5CRT (2) W5CRT (2)
2.64ꢀ
2.53ꢀ
1.52
U5CRT (2)
YA6C-N-45
YA6C-N-90
YA6C
#6 AWG
-
1/2ꢀ
1/4ꢀ
1/4ꢀ
1/2ꢀ
.83ꢀ
.41ꢀ
.44ꢀ
.83ꢀ
Blue
7
1-3/16ꢀ
Y2MR (2)
X5CRT (2) X5CRT (2)
U8CABT (2)
Y644M (1) X8CART (2) X8CART (2)
Y1MR (1)
1.81ꢀ
1.24ꢀ
.81ꢀ
YA6C-45
YA6C-90
YA5C
YA5C-45
1.98ꢀ
1.75ꢀ MRC840 (2)
Y1MR (1)
W5CVT (2) W5CVT (2)
W5CRT (2) W5CRT (2)
X5CRT (2) X5CRT (2)
YA5C-90
YA5C-N
.81ꢀ
2.67ꢀ MY29-11 (2)
MY29-3 (2)
#5 AWG
#4 AWG
-
U5CRT (2)
Blue
Gray
7
8
1-3/16ꢀ
1-3/16ꢀ
YA5C-N-45
YA5C-N-90
YA4C-TC10
YA4C-TC10-45
YA4C-TC10-90
YA4C
2.55ꢀ
1.52ꢀ
Y2MR (2)
Y644M (1)
1.94ꢀ MRC840 (2)
1.94ꢀ MY29-3 (2) W4CVT (2) W4CVT (2)
1.75ꢀ MY29-11 (2) W4CRT (2) W4CRT (2)
# 10 .49ꢀ
1.12ꢀ .09ꢀ
1.12ꢀ .09ꢀ
U4CRT (2)
U6CABT (2)
1.87ꢀ
1.52ꢀ
Y2MR (4)
Y644M (1)
X4CRT (2) X4CRT (2)
1/4ꢀ
.50ꢀ
YA4C-45
*
Use PUADP-1 adapter with "U" dies in Y46 HYPRESS™.
†
The MM2 conductor size listed is for Class 2 and Class 5
conductor.
•
Available undrilled. Add suffix "U" to catalog number
(example: YA25U).
◆ For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.
** P-RT die sets for use in Y46 HYPRESS™ only, PUADP-1
adapter not required.
*** The MM2 conductor sizes listed are the recommendations
for Class 2 conductor.
◆ See tooling section of this catalog for complete tool and die
listings. Use ONLY color coded die recommendations for "-
FX" connectors. For nest/indentor system contact factory.