霍尼韦尔 - HONEYWELL 监视器
页数 文件大小 规格书
2页 148K
描述
Ten-Input Monitor Module

XP10-M 数据手册

 浏览型号XP10-M的Datasheet PDF文件第2页 
DN-6923:A1 • H-352  
XP 1 0 -M  
Te n -In p u t Mo n it o r Mo d u le  
Ad d re s s a b le De vic e s  
Ge n e ra l  
The XP10-M ten-input monitor module provides an interface  
between a control panel and normally open contact devices in  
intelligent alarm systems such as pull stations, security con-  
tacts, or flow switches.  
The first address on the XP10-M is set from 01 to 150 and the  
remaining modules are automatically assigned to the next nine  
higher addresses. Provisions are included for disabling a maxi-  
mum of two unused addresses.  
The supervised state (normal, open, or short) of the monitored  
device is sent back to the panel. A common SLC input is used  
for all modules, and the initiating device loops share a common  
supervisory supply and ground — otherwise each monitor oper-  
ates independently from the others.  
Each XP10-M module has panel-controlled green LED indica-  
tors. The panel can cause the LEDs to blink, latch on, or latch off.  
Fe a t u re s  
6923xp10.jpg  
Ten addressable Class B or five addressable Class A initiat-  
ing device circuits.  
Removable 12 AWG (3.31 mm²) to 18 AWG (0.821 mm²)  
plug-in terminal blocks.  
Maximum IDC wiring res is tance: 1500 ohms.  
Status indicators for each point.  
Maximum IDC voltage: 12 VDC.  
Maximum IDC current: 1 mA.  
Unused addresses may be disabled.  
Rotary address switches.  
Class A or Class B operation.  
Ag e n c y Lis t in g s a n d Ap p ro va ls  
FlashScan® or CLIP operation.  
Mount one or two modules in a BB-XP cabinet (optional).  
The listings and approvals below apply to the XP10-M Ten-Input  
Monitor Module. In some cases, certain modules or applications  
may not be listed by certain approval agencies, or listing may be  
in process. Consult factory for latest listing status.  
Mount up to six modules on a CHS-6 chassis in a CAB-3  
Series, CAB-4 Series, EQ Cabinet Series, or BB-25 cabinet  
(optional).  
UL Listed: file S3705.  
Mounting hardware included.  
ULC Listed: file S635 (XP10-MA).  
CSFM approved: file 7300-0028:219.  
FM approved.  
S p e c ific a t io n s  
Standby current: 3.5 mA (SLC current draw with all addresses  
used; if some addresses are disabled, the standby current  
decreases).  
MEA approved: file 43-02-E.  
Maryland State Fire Mars hal approved: Permit #2106.  
Alarm current: 55 mA (assumes all ten LEDs solid ON).  
P ro d u c t Lin e In fo rm a t io n  
XP10-M: Ten-input monitor module.  
Temperature range: 32°F to 120°F (0°C to 49°C) for UL appli-  
cations; –10°C to +55°C for EN54 applications.  
Humidity: 10% to 85% noncondensing for UL applications; 10%  
to 93% noncondensing for EN54 applications.  
XP10-MA: Same as above with ULC Listing.  
BB-XP: Optional cabinet for one or two modules. Dimensions,  
DOOR: 9.234" (23.454 cm) wide (9.484" [24.089 cm] including  
hinges), x 12.218" (31.0337 cm) high, x 0.672" (1.7068 cm)  
deep; BACKBOX: 9.0" (22.860 cm) wide (9.25" [23.495 cm]  
including hinges), x 12.0" (30.480 cm) high x 2.75" (6.985 cm);  
CHASSIS (installed): 7.150" (18.161 cm) wide overall x 7.312"  
(18.5725 cm) high interior overall x 2.156" (5.4762 cm) deep  
overall.  
Dimens ions : 6.8" (172.72 mm) high x 5.8" (147.32 mm) wide x  
1.25" (31.75 mm) deep.  
Shipping weight: 1.1 lb. (0.499 kg) including packaging.  
Mounting options : CHS-6 chassis, BB-25 cabinet, BB-XP cab-  
inet, CAB-3 Series cabinet (see DN-3549), CAB-4 Series cabi-  
net (see DN-6857), or EQ Cabinet Series (see DN-60229).  
Wire gauge: 12 AWG (3.31 mm²) to 18 AWG (0.821 mm²).  
BB-25: Optional cabinet for up to six modules mounted on  
CHS-6 chassis (below). Dimensions, DOOR: 24.0" (60.96 cm)  
wide x 12.632" (32.0852 cm) high, x 1.25" (3.175 cm) deep,  
hinged at bottom; BACKBOX: 24.0" (60.96 cm) wide x 12.550"  
(31.877 cm) high x 5.218" (13.2537 cm) deep.  
Power-limited circuits must employ type FPL, FPLR, or FPLP  
cable as required by Article 760 of the NEC.  
XP10-M is s hipped in Clas s B pos ition; remove shunt for  
Class A operation.  
Maximum SLC wiring res is tance: 40 or 50 ohms, panel  
dependent.  
CHS-6: Chassis, mounts up to six modules in a CAB-3 Series  
(see DN-3549), CAB-4 Series (see DN-6857) cabinet, EQ Cabi-  
net Series (see DN-60229), or BB-25.  
DN-6923:A1 • 8/3/07 — Page 1 of 2  

与XP10-M相关器件

型号 品牌 获取价格 描述 数据表
XP1101 PANASONIC

获取价格

Small Signal Bipolar Transistor, 0.03A I(C), 40V V(BR)CEO, 2-Element, PNP, Silicon,
XP1101TX PANASONIC

获取价格

Small Signal Bipolar Transistor, 0.03A I(C), 40V V(BR)CEO, 2-Element, PNP, Silicon,
XP1110 PANASONIC

获取价格

Silicon PNP epitaxial planer transistor
XP1110TX PANASONIC

获取价格

Small Signal Bipolar Transistor, 0.1A I(C), 50V V(BR)CEO, 2-Element, PNP, Silicon
XP1111 PANASONIC

获取价格

Silicon PNP epitaxial planer transistor
XP1111TX PANASONIC

获取价格

Small Signal Bipolar Transistor, 0.1A I(C), 50V V(BR)CEO, 2-Element, PNP, Silicon
XP1112 PANASONIC

获取价格

Silicon PNP epitaxial planer transistor
XP1112TX PANASONIC

获取价格

Small Signal Bipolar Transistor, 0.1A I(C), 50V V(BR)CEO, 2-Element, PNP, Silicon
XP1113 PANASONIC

获取价格

Silicon PNP epitaxial planer transistor
XP1113TX PANASONIC

获取价格

Small Signal Bipolar Transistor, 0.1A I(C), 50V V(BR)CEO, 2-Element, PNP, Silicon