TRUMPower
The TUP110 series of AC/DC switching power
supplies are for 110 watts of continuous output
110 WATT POWER ADAPTERS
DESCRIPTION
TUP110 SERIES
(LVD+EMC)
power. They are enclosed in
a
94V-1 rated
polyphenylene-oxide case with an IEC 320 inlet to
mate with interchangeable cord for world-wide
use. An on/off switch can be added at request. All
models meet CISPR 22 and FCC class B emission
limits, and comply with UL, CSA, IEC and CE
requirements.
FEATURES
‧ Single, dual, triple or quadruple outputs
‧ Optional output connectors
‧ Optional on/off switch
Safety Standard Approvals:
UL 60950-1
CSA C22.2 No. 60950-1
‧ Optional Power Fail Detect (PFD) signal
‧ 100% burn-in
‧ Wide input range 85 to 264 VAC
‧ Input surge current protection
‧ Overvoltage protections
TÜV EN60950-1
‧ Overcurrent protections
ENVIRONMENTAL SPECIFICATIONS
INPUT SPECIFICATIONS
Operating temperature:
Storage temperature:
Relative humidity:
Derating:
0ºC to +70ºC
Input voltage:
Input frequency: 47 to 63 Hz
Input current: 3.20A( rms) for 115VAC
1.80A( rms) for 230VAC
85 to 264 VAC
-40ºC to +85ºC
5% to 95% non-condensing
Derate from 100% at +50ºC
linearly to 50% at +70ºC
Leakage current: 0.40mA max. @ 115VAC, 60Hz
0.80mA max. @ 230VAC, 50Hz
OUTPUT SPECIFICATIONS
Output voltage/current: See rating chart
GENERAL SPECIFICATIONS
Switching frequency: 20K to 250KHz, varies with load and
Total output power:
Ripple and noise:
Overvoltage protection: Provided on output #1 only; set
at 112 – 132% of its nominal
110 watts maximum
1% peak to peak maximum
line
Efficiency:
70% minimum on single output
models with Vo ≥12V, 65% minimum
on the others
output voltage
Hold-up time:
Line regulation:
Inrush current:
12 msec minimum at 110VAC
±0.5% maximum at full load
15 amps @ 115VAC, or 30 amps
@ 230VAC, at 25ºC cold start
3000VAC from input to output
1500VAC from input to ground
500VAC from output to ground
550,000 hours minimum at full load
at 25ºC ambient , calculated per
MIL-HDBK-217F, excluding DC fan
Overcurrent protection: All outputs protected to short
circuit conditions
Temperature coefficient: All outputs ±0.04%/ºC
maximum
Withstand voltage:
MTBF:
Transient response:
Maximum excursion of 4% or
better on all models, recovering
to 1% of final value within
500µs after a 25% step load
change
TTL logic high for normal
operation and TTL logic low
upon loss of input power. This
signal appears at least 1ms
prior to +5V output dropping
5% below its nominal value.
This signal also provides a
minimum delay of 100ms after
+5V is within regulation.
EMC performance (EN55024)
EN55022:
FCC:
VCCI:
EN61000-3-2:
EN61000-3-3:
EN61000-4-2:
EN61000-4-3:
EN61000-4-4:
EN61000-4-5:
EN61000-4-6:
EN61000-4-8:
PFD signal (optional):
Class B conducted, class B radiated
Class B conducted, class B radiated
Class B conducted, class B radiated
Harmonic distortion, class A
Line flicker
ESD, ±8KV air and ±4KV contact
Radiated immunity, 3V/m
Fast transient/burst, ±1KV
Surge, ±1KV diff, ±2KV com.
Conducted immunity, 3Vrms
Magnetic field immunity, 1A/m
EN61000-4-11: Voltage dips, 30% reduction for 500ms and
>95% reduction for 10ms
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA
Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: sales@trumpower.com ● Website: www.TRUMPower.com