1500W True Sine Wave DC-AC Inverter with Solar Charger
TN-1500 series
Features :
True sine wave output (THD<3%)
High surge power up to 3000W
U.P.S. mode and energy saving mode (selectable)
High efficiency up to 91%
Power ON-OFF switch
Standby saving mode can be selectable
Front panel indicator for operation status
Thermostatically controlled cooling fan
Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp.
/ Output short / Input polarity reverse / Overload / AC circuit breaker
Application : Home appliance, power tools, office and portable
equipment, vehicle and yacht ...etc.
Built-in solar / AC charger
Optional monitoring software
2 years warranty
13
E
SPECIFICATION
MODEL
TN-1500-112
TN-1500-124
TN-1500-148
TN-1500-212
TN-1500-224
TN-1500-248
RATED POWER (Typ.)
1500W
MAXIMUM OUTPUT POWER 1725W for 180 sec. / 2250W for 10 sec. / surge power 3000W for 30 cycles
Factory setting set at 110VAC
Factory setting set at 230VAC
AC VOLTAGE
100 / 110 / 115 / 120VAC selectable by setting button S.W
60 0.1Hz 50/60Hz selectable by setting button S.W
True sine wave (THD<3%) at rated input voltage
3.0%
200 / 220 / 230 / 240VAC selectable by setting button S.W
50 0.1%Hz 50/60Hz selectable by setting button S.W
FREQUENCY
OUTPUT
WAVEFORM
AC REGULATION (Typ.)
TRANSFER TIME
SAVING MODE (Typ.)
FRONT PANEL INDICATOR
BAT. VOLTAGE
t<10ms inverter
Load 5W will be changed to standby mode
Battery voltage level, output load level, saving mode, fault and operation status
by pass
24V
48V
24V
48V
12V
12V
VOLTAGE RANGE (Typ.)Note.1 10.5 ~ 15VDC
21 ~ 30VDC
75A
42 ~ 60VDC
37.5A
10.5 ~ 15VDC
150A
21 ~ 30VDC
75A
42 ~ 60VDC
37.5A
DC CURRENT (Typ.)
Note.5 150A
18W @ standby saving mode
INPUT
NO LOAD DISSIPATION
OFF MODE CURRENT DRAW
1mA
EFFICIENCY (Typ.)
BATTERY TYPES
FUSE
Note.2 87%
89%
90%
88%
90%
91%
Open & sealed Lead Acid
40A*5
30A*3
30A*2
45 4%
42 4%
40A*5
30A*3
30A*2
45 4%
42 4%
BATTERY
INPUT
PROTECTION
11.3 4%
22.5 4%
21 4%
11.3 4%
10.5 4%
22.5 4%
21 4%
BAT. LOW ALARM
BAT. LOW SHUTDOWN
REVERSE POLARITY
10.5 4%
By internal fuse open
82
5
82
5
96
5
68
5
68
5
68
5
OVER TEMPERATURE
OUTPUT SHORT
Protection type : Shut down o/p voltage, re-power on to recover ; by internal RTH3 detect on heatsink of power transistor
Protection type : Shut down o/p voltage, re-power on to recover
OUTPUT
PROTECTION
105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec.
OVER LOAD (Typ.)
Protection type : Shut down o/p voltage, re-power on to recover
CIRCUIT BREAKER
GFCI PROCTECTION
WORKING TEMP.
20A
10A
Optional (Only type F)
None
0 ~ +40 @ 100% load ; 60 @ 50% load
Note.3
20% ~ 90% RH non-condensing
-30 ~ +70 / -22 ~ +158oF, 10 ~ 95% RH
WORKING HUMIDITY
ENVIRONMENT
STORAGE TEMP., HUMIDITY
VIBRATION
10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
UL458 (only for "GFCI" receptacles-Type F )
EN60950-1
SAFETY STANDARDS
Bat I/P - AC I/P:3.0KVAC Bat I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC
Compliance to EN55022 class B, 72/ 245/ CEE, 95/ 54/ CE, E-Mark
Compliance to EN61000-4-2,3,4,5,6,8,11 ENV50204
SAFETY & WITHSTAND VOLTAGE
EMC
EMI CONDUCTION&RADIATION Compliance to FCC class A
-----
EMS IMMUNITY
2.7A
1.35A
57V 4%
75V
2.7A
1.35A
57V 4%
75V
CHARGE CURRENT (Typ.)
5.5A
5.5A
AC
CHARGER CHARGE VOLTAGE
28.5V 4%
45V
28.5V 4%
45V
14.3V 4%
14.3V 4%
25V
MAX OPEN CIRCUIT VOLTAGE 25V
SOLAR
CHARGER
CHARGE CURRENT (max.)
CHARGE VOLTAGE
CONTROL WIRING
DIMENSION
30A
28.5V 4%
57V 4%
28.5V 4%
57V 4%
14.3V 4%
14.3V 4%
RJ11 -RS232 (Option)
OTHERS
NOTE
420*220*88mm (L*W*H)
6.85Kg; 2pcs/14.7Kg/1.61CUFT
PACKING
1.Output derating capacity referenced by curve 1.
2.Efficiency is tested by 1000W, linear load at 13V, 26V, 52V input voltage.
3.Output derating capacity referenced by curve 2.
4.All parameters not specified above are measured at rated load, 25 of ambient temperature.
5.DC current is tested by 1500W, linear load at 13V, 26V, 52V input voltage.
File Name:TN-1500-SPEC 2008-07-29