S101N11/S101N12/S201N11/S201N12
Voltage Input Type
Solid State Relay
with Built-in Snubber Circuit
S101N11/S101N12
S201N11/S201N12
■ Features
■ Outline Dimensions
(Unit : mm)
1. Built-in snubber circuit
26.0MAX.
5.5MAX.
2. Input side voltage operation type
3. Built-in zero-cross circuit (S101N12/S201N12)
4. RMS ON-state current IT : MAX. 1.6Arms
Lot No.
(DIN Standard)
S101N11
INPUT
OUTPUT
■ Applications
5VDC 1.6A120VAC
− +
1. Programmable controllers
2. Copiers
2.54
0.5
1.3±0.3
3. Air conditioners
2.54
10.16 7.62
4. Automatic vending machines
Model No.
S101N11
S101N12
S201N11
S201N12
■ Model line-ups
4
3
2
1
For 100V lines
S101N11
S101N12
For 200V lines
S201N11
S201N12
No zero-cross circuit
Built-in zero-cross circuit
Internal connection diagram
S101N11/S201N11 S101N12/S201N12
■ Absolute Maximum Ratings
(Ta=25°C)
Unit
V
Rating
Parameter
Input signal voltage
Reverse voltage
Symbol
VIN
3 to 6
6
Input
V
VR
S101N11
120
240
S101N12
S201N11
S201N12
Standard
voltage
−
f
Vrms
Hz
4
3
2
1
4
3
2
1
Z.C. : Zero-cross circuit
1
2
3
4
1
Output (Triac T1)
Output (Triac T2)
Input (+)
Output (Triac T1)
Output (Triac T2)
Input (+)
Input (−)
Operating frequency
47 to 63
2
3
Output
S101N11
S101N12
60 to 140
4
Output
supply
voltage
Input (−)
Vout
Vrms
❈ Unspecified tolerance : ±0.4mm
S201N11
S201N12
60 to 280
*11.6
15
IT
Arms
A
RMS ON-state current
Peak one cycle surge current
Operating temperature
Storage temperature
*2
Isurge
Topr
Tstg
Viso
−25 to +80
−30 to +85
3.0
°C
°C
*3Isolation voltage
kVrms
°C
*4
Soldering temperature
260
Tsol
*1 Refer to Fig.1
*2 50Hz sine wave, start at Tj=25°C
*3 Isolation voltage measuring method
(1) Dielectric withstand voltage tester with zero cross circuit shall be used.
(2) The applied voltage waveform shall be sine wave.
(3) Voltage shall be applied between input and output.
(Input and output terminals shall be shorted respectively.)
(4) AC 60Hz, 1min, 40 to 60%RH.
*4 For 5s
Notice
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP
devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
Internet Internet address for Electronic Components Group http://www.sharp.co.jp/ecg/