S101S05V/S101S06V/S201S05V/S201S06V
SIP Type SSR with
Mounting Capability for
External Heat Sink
S101S05V/S101S06V
S201S05V/S201S06V
( )
Unit : mm
■ Features
1. High radiation resin mold package.
2. RMS ON-state current
■ Outline Dimensions
* The metal parts marked *
are common to terminal 1 .
❈ Do not allow external connection.
: Typical dimensions
( )
18.5±
16.4±
0.2
IT : MAX. 3Arms at T <=100˚C
C
0.3
(
)
With heat sink
3. Isolation voltage between input and output
±
0.2
0.2
φ
3.2
5.5±
(
)
A
Model No.
B
*
S101S05V
S101S06V
S201S05V
S201S06V
(
)
V : 3 000 V
iso
rms
3A125VAC
4. Built-in zero-cross circuit
3A265VAC
(
)
S101S06V/S201S06V
A
B
5. Recognized by UL, file No. E94758
Approved by CSA, No. LR63705
+
-
±
0.2
-
-
-
4
4
4
1.1
±
0.3
1.25
■ Applications
±
0.2
0.8
1. OA equipment such as copiers
2. FA equipment
1
2
3
4
(
0.1
( )
1.4
(
) (
)
)
0.6±
5.08 7.62
2.54
■ Model Line-ups
Internal connection diagram
S101S05V /S201S05V
S101S06V /S201S06V
For 100V lines
For 200V lines
No built-in
zero-cross circuit
S101S05V
S201S05V
S201S06V
Zero-cross
circuit
Built-in
zero-cross circuit
S101S06V
1
2
3
4
1
2
3 4
(
)
)
(
Output Triac T2
)
)
1
2
3
4
Output Triac T2
1
2
3
4
(
(
Output Triac T1
Output Triac T1
( + )
( - )
( + )
( - )
Input
Input
Input
Input
(
)
■ Absolute Maximum Ratings
Ta = 25˚C
Rating
Parameter
Symbol
Unit
S101S05V / S101S06V S201S05V / S201S06V
Forward current
Input
IF
VR
IT
50
6
mA
V
A rms
A
V
V
A/ µ s
Hz
V rms
˚C
˚C
˚C
Reverse voltage
RMS ON-state current
*43
30
*1Peak one cycle surge current
Isurge
V DRM
V DSM
dIT /dt
f
V iso
T opr
T stg
T sol
Repetitive peak OFF-state voltage
Non-repetitive peak OFF-state voltage
400
400
600
600
Output
Critical rate of rise of ON-state current
Operating freguency
40
45 to 65
3 000
- 25 to + 100
- 30 to + 125
260
*2 Isolation voltage
Operating temperature
Storage temperature
*3Soldering temperature
*1 60Hz sine wave, start at Tj= 25˚C
*2 60Hz AC for 1 minute, 40 to 60% RH. Apply voltages between input and output, by the dielectric withstand
(
)
voltage tester with zero-cross circuit. Input and output shall be shorted respectively
(
)
Note When the isolation voltage is necessary at using external heat sink, please use the insulation sheet.
*3 For 10 seconds
*4 Tc<=100˚C
“ In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,
data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device.”