Nexperia
PMEG100T30ELR
100 V, 3 A low leakage current Trench MEGA Schottky barrier rectifier
10. Characteristics
Table 7. Characteristics
Symbol
Parameter
Conditions
Min
Typ
Max
Unit
V(BR)R
reverse breakdown
voltage
IR = 1 mA; pulsed; Tj = 25 °C
[1]
100
-
-
V
VF
forward voltage
IF = 0.5 A; pulsed; Tj = 25 °C
IF = 1 A; pulsed; Tj = 25 °C
IF = 2 A; pulsed; Tj = 25 °C
IF = 3 A; pulsed; Tj = 25 °C
IF = 3 A; pulsed; Tj = -40 °C
IF = 3 A; pulsed; Tj = 125 °C
IF = 3 A; pulsed; Tj = 150 °C
VR = 60 V; pulsed; Tj = 25 °C
VR = 100 V; pulsed; Tj = 25 °C
VR = 100 V; pulsed; Tj = 125 °C
VR = 100 V; pulsed; Tj = 150 °C
VR = 1 V; f = 1 MHz; Tj = 25 °C
VR = 10 V; f = 1 MHz; Tj = 25 °C
[1]
[1]
[1]
[1]
[1]
[1]
[1]
[1]
[1]
[1]
[1]
-
-
-
-
-
-
-
-
-
-
-
-
-
-
480
540
630
705
705
580
545
0.1
550
610
710
800
800
650
620
0.8
1.75
2.2
8
mV
mV
mV
mV
mV
mV
mV
µA
IR
reverse current
0.25
0.42
1.65
310
90
µA
mA
mA
pF
Cd
trr
diode capacitance
-
-
pF
reverse recovery time IF = 0.5 A; IR = 0.5 A; IR(meas) = 0.1 A;
step recovery Tj = 25 °C
9
-
ns
reverse recovery time dIF/dt = 200 A/µs; IF = 6 A; VR = 26 V;
ramp recovery Tj = 25 °C
-
-
-
-
12.5
1.3
-
-
-
-
ns
A
IRM
peak reverse recovery dIF/dt = 200 A/s; IF = 6 A; VR = 26 V;
current
Tj = 25 °C
Qrr
reverse recovery
charge
10
nC
mV
VFRM
peak forward recovery IF = 0.5 A; dIF/dt = 20 A/µs; Tj = 25 °C
voltage
480
[1] Very short pulse, in order to maintain a stable junction temperature.
©
PMEG100T30ELR
All information provided in this document is subject to legal disclaimers.
Nexperia B.V. 2021. All rights reserved
Product data sheet
12 July 2021
4 / 14