5秒后页面跳转
PBA75F-48-N PDF预览

PBA75F-48-N

更新时间: 2024-09-16 08:00:31
品牌 Logo 应用领域
科索 - COSEL /
页数 文件大小 规格书
14页 2312K
描述
AC-DC Regulated Power Supply Module, 76.8W

PBA75F-48-N 数据手册

 浏览型号PBA75F-48-N的Datasheet PDF文件第2页浏览型号PBA75F-48-N的Datasheet PDF文件第3页浏览型号PBA75F-48-N的Datasheet PDF文件第4页浏览型号PBA75F-48-N的Datasheet PDF文件第5页浏览型号PBA75F-48-N的Datasheet PDF文件第6页浏览型号PBA75F-48-N的Datasheet PDF文件第7页 
Ordering information  
AC-DC Power Supplies Enclosed Type  
PB  
A
10  
F
-O -O  
5ꢀ 6  
PBA10F  
1ꢀ  
2ꢀ  
3ꢀ  
4ꢀ  
1Series name  
2Single output  
3Output wattage  
4Universal input  
5Output voltage  
Example recommended EMI/EMC filter  
NAC-06-472  
R
6Optional *5  
C :with Coating  
G :Low leakage current  
E :Low leakage current  
and EMI class A  
T :Vertical terminal block  
J :Connector type  
N :with Cover  
(UL508 is acquired)  
N1 :with DIN rail and Cover  
V :Output voltage setting  
potentiometer external-  
ly  
High voltage pulse noise type : NAP series  
Low leakage current type : NAM series  
*
Ahigher current rating EMI/EMC filter  
may be recommended in view of the  
other devices that could be connected  
in parallel with the power supply.  
Cover is optional  
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.  
MODEL  
MAX OUTPUT WATTAGE[W]  
DC OUTPUT  
PBA10F-5  
10  
5V 2A  
PBA10F-12  
10.8  
12V 0.9A  
PBA10F-24  
12  
24V 0.5A  
SPECIFICATIONS  
MODEL  
PBA10F-5  
PBA10F-12  
PBA10F-24  
(
)
3
*
VOLTAGE[V]  
AC85 - 264 1 or DC110 - 370 AC50 or DC70 Please refer to the instruction manual 2.1 Input voltage  
f
(
(
)
)
ACIN 100V 0.30typ Io=100%  
CURRENT[A]  
ACIN 200V 0.20typ Io=100%  
( )  
50/60 47 - 440 or DC  
FREQUENCY[Hz]  
INPUT  
ACIN 100V 74typ  
ACIN 200V 74typ  
76typ  
76typ  
77typ  
77typ  
EFFICIENCY[%]  
(
(
)
)
ACIN 100V 15typ Io=100%  
INRUSH CURRENT[A]  
ACIN 200V 30typ Io=100%  
(
,
,
,
)
LEAKAGE CURRENT[mA]  
VOLTAGE[V]  
0.15/0.30max ACIN 100V/240V 60Hz Io=100% According to IEC60950-1 DENAN  
5
12  
24  
CURRENT[A]  
2
0.9  
0.5  
6
6
1
1
1
1
*
*
*
*
*
*
LINE REGULATION[mV]  
LOAD REGULATION[mV]  
20max  
40max  
80max  
140max  
120max  
160max  
50max  
48max  
100max  
120max  
160max  
150max  
180max  
120max  
150max  
48max  
96max  
150max  
120max  
160max  
150max  
180max  
240max  
290max  
96max  
0
to +50  
C
RIPPLE[mVp-p]  
-10 - 0  
C
0
to +50  
C
RIPPLE NOISE[mVp-p]  
OUTPUT  
-10 - 0  
C
0 to +50  
C
TEMPERATURE REGULATION[mV]  
-10 to +50 60max  
C
2
*
DRIFT[mV]  
20max  
(
,
)
200typ ACIN 100V Io=100%  
*
START-UP TIME[ms]  
HOLD-UP TIME[ms]  
Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.  
)
(
,
20typ ACIN 100V Io=100%  
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 4.50 - 5.50  
OUTPUT VOLTAGE SETTING[V] 5.00 - 5.15  
10.0 - 13.2  
12.00 - 12.48  
19.2 - 27.0  
24.00 - 24.96  
OVERCURRENT PROTECTION Works over 105% of rated current and recovers automatically  
PROTECTION  
CIRCUIT AND  
OTHERS  
OVERVOLTAGE PROTECTION[V] 5.75 - 7.00  
15.0 - 18.0  
30.0 - 37.0  
(
)
OPERATING INDICATION  
REMOTE ON/OFF  
LED Green  
None  
, , , (  
AC3 000V 1minute Cutoff current = 10mA DC500V 50M min At Room Temperature  
W
)
INPUT-OUTPUT  
, , , (  
AC2 000V 1minute Cutoff current = 10mA DC500V 50M min At Room Temperature  
W
)
ISOLATION INPUT-FG  
OUTPUT-FG  
,
,
(
)
AC500V 1minute Cutoff current = 25mA DC500V 50M min At Room Temperature  
W
,
(
),  
(
)
,
(
,
)
OPERATING TEMP. HUMID.AND ALTITUDE -10 to +71  
Required Derating 20 - 90%RH Non condensing 3 000m 10 000feet max  
C
,
,
(
)
,
(
,
)
STORAGE TEMP. HUMID.AND ALTITUDE -20 to +75  
20 - 90%RH Non condensing 9 000m 30 000feet max  
C
ENVIRONMENT  
2
,
(
),  
,
,
VIBRATION  
IMPACT  
10 - 55Hz 19.6m/s 2G 3minutes period 60minutes each along X Y and Z axis  
196.1m/s2 20G 11ms once each X Y and Z axis  
(
),  
,
,
(
)
,
(
),  
,
AGENCY APPROVALS At only AC input UL60950-1 C-UL CSA60950-1 EN60950-1 EN50178 Complies with DEN-AN  
SAFETY AND  
NOISE  
REGULATIONS  
,
,
,
,
CONDUCTED NOISE  
HARMONIC ATTENUATOR Complies with IEC61000-3-2 Not built-in to active filter  
Complies with FCC Part15 classB VCCI-B CISPR22-B EN55011-B EN55022-B  
7
(
)
*
4
*
(
) ( )  
W H  
X X  
(
)
CASE SIZE/WEIGHT  
COOLING METHOD  
31 78 68mm [1.22 3.07 2.68 inches] without terminal block  
Convection  
D / 150g max with cover : 180g max  
X
X
X
X
OTHERS  
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN  
*5 Please contact us about safety approvals for the model with option.  
*6 Please contact us about dynamic load and input response.  
*7 Please contact us about class C.  
:RM101).  
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.  
*3 Derating is required.  
*4 When two or more units are used,they may not comply with the harmonic attenuator. Please  
contact us for details.  
*
*
*
Parallel operation with other model is not possible.  
Derating is required when operated with cover.  
A sound may occur from power supply at peak loading.  
PBA/PBW-2  

与PBA75F-48-N相关器件

型号 品牌 获取价格 描述 数据表
PBA75F-5 XPPOWER

获取价格

AC-DC Chassis Mount
PBA75F-5 RSG

获取价格

Unit type
PBA75F-9 RSG

获取价格

Unit type
PBA75F-9 XPPOWER

获取价格

AC-DC Chassis Mount
PBAS HAMMOND

获取价格

Adaptateur de rails pour montage sur bati de 24 a 19 po
PBAS19001 HAMMOND

获取价格

DATA SUBJECT TO CHANGE WITHOUT NOTLCE
PBAS19001BK2 HAMMOND

获取价格

Adaptateur de rails pour montage sur bati de 24 a 19 po
PBAS19001CG2 HAMMOND

获取价格

DATA SUBJECT TO CHANGE WITHOUT NOTLCE
PBAS19001LG2 HAMMOND

获取价格

Adaptateur de rails pour montage sur bati de 24 a 19 po
PBAS19003 HAMMOND

获取价格

DATA SUBJECT TO CHANGE WITHOUT NOTLCE