AC-DC Chassis Mount
50-150 Watts
PBA Series
TH E X P E R T S IN PO W E R
Universal PFC Input
•
•
Convection Cooled
•
Low Profile <1U
•
Adjustable Output Voltage
•
Optional Remote On/Off
•
Optional Din Rail Mount
•
High Efficiency
Specification
Input
General
Efficiency
Isolation
Input Voltage
•
85-264 VAC (120-370 VDC)
•
•
85% typical
50 VAC (70 VDC) (Optional, contact
sales)
3000 VAC Input to Output
2000 VAC Input to Ground
500 VAC Output to Ground
Input Frequency
Input Current
•
•
•
•
•
47-63 Hz
Switching Frequency
Indications
•
•
60-550 kHz PFC, 130kHz PWM
Green LED for unit operating
2/1 A max at 115/230 VAC
20/40 A max at 115/230 VAC
EN61000-3-2 compliant
Inrush Current
Power Factor
Leakage Current
0.75 mA max, optional 0.15 mA - add
suffix “-G” to model numbers
Environmental
Operating
Temperature
•
-10 °C to +70 °C, see derating curve
-20 °C to +75 °C
Output
Storage
Temperature
•
Output Voltage
Output Voltage
Adjustment
•
•
3.3 VDC to 48 VDC
+10/-15%
Relative Humidity
Shock
•
•
•
20-90% non-condensing
20 G 11 ms, onceeach x, y and z axis
2 G 10-55Hz for 3 min periods for
60 min along each x, y and z axis
Output Voltage
Set Point
•
±3% Vnom
Vibration
Minimum Load
Start-Up Time
Drift
•
•
•
•
•
•
No minimum load required
350 ms typical
EMC & Safety
Emissions
±0.6% max
•
•
•
EN55022 Level B conducted
EN55022 Level B radiated
Line Regulation
Load Regulation
Hold-up Time
±1% max
ESD
Susceptibility
EN61000-4-2 Level 4
EN61000-4-3 Level 3
EN61000-4-4 Level 4
±2% max
15 ms typical
Radiated
Susceptibility
Output Ripple & Noise •
1% of Vn pk-pk
operates at 120-140% of Vnom
Overvoltage
Protection
•
EFT/Burst
Surge
•
•
EN61000-4-5 Level 3 line to line
EN61000-4-5 Level 4 line to earth
Overload Protection
•
Operates at 105% of rated current,
autorecovery
Voltage dips and
interruptions
•
•
EN61000-4-11
Remote ON/OFF
•
Optional. Add suffix “-R” to model
number
Safety Approvals
UL60950, CSA 60950
EN60950, EN50178
•
•
www.xpplc.com
sales@xpplc.com